• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.17.2007.tde-26092013-155810
Document
Author
Full name
Luiz Alberto Manetta
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2007
Supervisor
Committee
Ferriani, Rui Alberto (President)
Berezowski, Aderson Tadeu
Busso, Newton Eduardo
Pastore, Ayrton Roberto
Reis, Rosana Maria dos
Title in Portuguese
O efeito do sistema intra-uterino de levonorgestrel (SIU-LNG) no fluxo das artérias uterinas, volume uterino e espessura endometrial em pacientes com endometriose pélvica: estudo comparativo com o análogo de GNRH (GnRHa)
Keywords in Portuguese
Análogo do hormônio liberador de gonadotrofina (GnRHa)
Doppler
Endometriose Pélvica
Sistema intra-uterino de levonorgestrel (SIU-LNG)
Abstract in Portuguese
Objetivos: O objetivo deste estudo foi comparar os índices de Pulsatilidade (IP) e Resistência (IR) das artérias uterinas, o volume uterino e a espessura endometrial após o uso do Sistema Intra-uterino de Levonorgestrel (SIU-LNG) ou do agonista do GnRHa (GnRHa) em pacientes portadoras de endometriose pélvica. Pacientes e métodos: Setenta e nove mulheres voluntárias, com idade entre 18 e 40 anos, foram incluídas neste ensaio clínico comparativo, prospectivo, randomizado e controlado. Dezoito foram eliminadas do estudo baseadas nos critérios de exclusão, As 61 pacientes remanescentes foram divididas em dois grupos: 31 pacientes fizeram parte do grupo SIU-LNG (uma foi excluída antes da inserção por apresentar-se grávida) e 30 fizeram parte do grupo GnRHa. Foram submetidasa exame ultra-sonográfico transvaginal bidimensional no dia em que iniciaram o tratamento (inserção do SIU-LNG ou administração de uma ampola de 3,75 mg de GnRHa por via intra-muscular) e seis meses após, avaliando a espessura endometrial, o volume uterino e os IR e IP das artérias uterinas. Resultados: Ambos tratamentos promoveram redução da espessura endometrial (6.08±3.00mm para 2.70±0.98mm e 6.96±3.82mm para 3.23±2.32mm - média ±SD, grupo SIU-LNG e grupo GnRHa, respectivamente). O volume uterino teve redução no grupo usuário do GnRHa (86.67±28.38cm3 para 55.27±25.52cm3) sem alteração significativa nas usuárias do SIU-LNG (75.77±20.88cm3 para 75.97±26.62cm3). Em relação à ascularização uterina, notamos incremento dos IP das artérias uterinas em ambos os grupos (grupo SIU-LNG: artéria uterina direita de 2.38±0.72 para 2.76±0.99 (média ±SD) e artéria uterina esquerda 2.46±0.70 para 2.87±0.96, e grupo GnRHa: artéria uterina direita 2.04±0.59 para 3.12±0.98 eartéria uterina esquerda 2.24±0.59 para 3.15±0.89). Em relação ao IR das artérias uterinas, observamos incremento no grupo GnRHa em ambas artérias e somente na artéria uterina esquerda no grupo SIU-LNG (grupoSIU-LNG - artéria uterina direita de 0.85±0.08 para 0.88±0.07 e artéria uterina esquerda de 0.86±0.07 para 0.89±0.06, e grupo GnRHa: artéria uterina direita de 0.81±0.07 para 0.93±0.09 e artéria uterina esquerda 0.84±0.06 para 0.93±0.09). No entanto, ao compararmos as diferenças, a elevação foi significativamente maior nas usuárias do GnRHa. Conclusões: Ambos GnRHa e SIU-LNG promoveram redução na espessura endometrial e aumento no IP das artérias uterinas. Houve redução do volume uterino nas usuárias do grupo GnRHa, não se alterando no grupo SIU-LNG. Em relação ao IR, houve incremento em ambas as artérias nas usuárias de GnRHa e somente na artéria uterina esquerda nas usuárias do SIU-LNG.
Title in English
The effect of System Intrauterine levonorgestrel (LNG-IUS) in the uterine artery flow, volume uterinoe Endometrial thickness in patients with endometriosis Pelvic: comparative study with the GnRH analogue (GnRHa)
Keywords in English
Doppler Ultrasonography.
Endometriosis
Gonadotropin Releasing Hormone
Levonorgestrel Intrauterine Device
Abstract in English
Objectives:The objective of the present study was to compare the uterine arteries pulsatility index (PI) and resistence index (IR), uterine volume and endometrial thickness changes promoted by the use of the levonorgestrel intrauterine device (LNG-IUD) and the gonadotropin-releasing hormone analogue (GnRHa)in patients with endometriosis. Methods: Seventy nine women aged 18 to 40 years were included in this randomized controlled trial. Eighteen was excluded based on the exclusion criteria. The patients were randomly allocated in two groups: 31 women who used the LNG-IUD (since one became pregnant before insertion and wasexcluded) and 30 who used monthly GnRHa injections. They were submitted to a transvaginal two dimensional ultrasound scan on the day the treatment started and 6 months later, for the evaluation of uterine arteries PI, uterine arteries RI, uterine volume and endometrial thickness. Results: The use of LNG-IUD promoted an ndometrial thickness decrease (6.08±3.00mm to 2.7±0.98mm; mean±SD) as does the use of GnRHa (6.96±3.82mm to 3.23±2.32mm). The uterine volume decreased in the GnRHa group (86.67±28.38cm3to 55.27±25.52cm3), but not in the LNG-IUD group (75.77±20.88cm3 to 75.97±26.62cm3). Uterine arteries PI increased in both groups : Uterine arteries PI: LNG-IUD right uterine arterie 2.38 ± 0.72 to 2.76 ± 0.99 and left uterine arterie 2.46 ± 0.70 to 2.87 ± 0.96, and GnRHa right uterine arterie 2.04 ± 0.59 to 3.12 ± 0.98 and left uterine arterie 2.24±0.59 to 3.15 ± 0.89. Uterine arteries RI increased in both arteries in GnRHa and only in the left uterine arterie in the LNG-IUD :Uterine arteries RI : LNG-IUD right uterine arterie 0.85 ± 0..08 to 0.88 ± 0.07 and left uterine arterie 0.86 ± 0.07 to 0.89 ± 0.06, and GnRHa right uterine arterie 0.81 ± 0.07 to 0.93 ± 0.09 and left uterine arterie 0.84 ± 0.06 to 0.93 ± 0.09 . However, the increase was significant higher in the GnRHa group. Conclusions: Both GnRHa and LNG-IUD promoted an endometrial thickness decrease and an increase in the uterine arteries PI. The uterine volume decreased in women who used GnRHa, but not in those who used LNG-IUD.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
DOUTORADOLUIZMANETTA.pdf (510.97 Kbytes)
Publishing Date
2014-08-27
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.