Disertación de Maestría
DOI
https://doi.org/10.11606/D.17.2006.tde-21092006-143828
Documento
Autor
Nombre completo
Luciano Albuquerque Lima Saraiva
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2006
Director
Tribunal
Santos, Antonio Carlos dos (Presidente)
Marques, Paulo Mazzoncini de Azevedo
Murta Junior, Luiz Otavio
Título en portugués
Desenvolvimento de software para processamento de imagens quantitativas em ressonância magnética
Palabras clave en portugués
desenvolvimento de software
DICOM
imagem médica
processamento de imagens
ressonância magnética
transferência de magnetização
Resumen en portugués
O uso de análise quantitativa em radiologia médica tem sido de grande valia na detecção de alterações não acessíveis à análise visual simples, dita qualitativa, seja por serem muito sutis, seja por não estarem presentes nas técnicas de imagem de ressonância magnética convencional. Porém, certos tipos de quantificação exigem a aquisição softwares e de plataformas computacionais de alto custo, além de mão de obra especializada com conhecimento técnico em computação para operar em ambientes não intuitivos. Neste cenário o objetivo deste trabalho foi a implementação de um software para análise de transferência de magnetização em imagens de ressonância magnética nuclear que funcionasse na plataforma IBM-PC e em sistemas operacionais livres como GNU/Linux. Com este intuito foi elaborado um algoritmo para leitura de imagens codificadas no padrão DICOM 3.0, um algoritmo para a construção dos mapas de Razão de Transferência de Magnetização do volume adquirido e um visualizador com interface amigável para a segmentação e análise dos resultados. Ao final, software possibilitou a abertura da imagem DICOM. Também construiu de maneira eficiente, os mapas de diferença de porcentagem entre as imagens sem e com o pulso de transferência de magnetização (MTR), possibilitando, inclusive, correções de artefatos de movimentos, quando pouco intensos. Permitiu o delineamento de regiões de interesse irregular, com boa visibilidade dos resultados. Como controle padrão, os resultados foram comparados com o conjunto de ferramentas da Universidade McGill (Brain Imaging Center, McGuill University, Montreal, Quebec, Canadá), amplamente testado em artigos publicados.
Título en inglés
Development of software for quantitative image processing in magnetic resonance
Palabras clave en inglés
DICOM
image processing
magnetic resonance
Magnetization Transfer
medical image
software development
Resumen en inglés
The use of quantitative analysis in medical radiology has been of great value in the detection of not accessible alterations in the simple visual analysis, said qualitative, for being very subtle, or for not being present in conventional magnetic resonance image techniques. However, certain types of quantification demand the acquisition of high cost softwares and computational platforms, beyond specialized workmanship, with technical knowledge in computation, to operate in non intuitive environments. In this scenery the objective of this work was the implementation of a software for analysis of transference of magneti zation in nuclear magnetic resonance images that works in IBM-PC platform and free operational systems as GNU/Linux. So, an algorithm for reading of standard DICOM 3.0 codified images was elaborated, an algorithm for the construction of Magnetization Transfer Ratio maps of acquired volume, and a visualizer with friendly interface for segmentation and analysis of the results. Finally the software made the opening of DICOM image possible. It also generated in efficient way the maps of percentage difference among the images without and with the pulse of magnetization transfer (MT), also making devices of movement corrections possible, when they are not very intense. It allowed the delineation of regions of irregular interest, with good visibility of the results. As standard control, the results were compared with the set of tools of the McGill University (Brain Imaging Center, McGuill University, Montreal, Quebec, Canada), widely tested in published articles. The elaborated program took care of the considered objectives.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
final.pdf (3.79 Mbytes)
Fecha de Publicación
2008-02-01
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.