• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.17.2006.tde-21092006-143828
Document
Author
Full name
Luciano Albuquerque Lima Saraiva
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2006
Supervisor
Committee
Santos, Antonio Carlos dos (President)
Marques, Paulo Mazzoncini de Azevedo
Murta Junior, Luiz Otavio
Title in Portuguese
Desenvolvimento de software para processamento de imagens quantitativas em ressonância magnética
Keywords in Portuguese
desenvolvimento de software
DICOM
imagem médica
processamento de imagens
ressonância magnética
transferência de magnetização
Abstract in Portuguese
O uso de análise quantitativa em radiologia médica tem sido de grande valia na detecção de alterações não acessíveis à análise visual simples, dita qualitativa, seja por serem muito sutis, seja por não estarem presentes nas técnicas de imagem de ressonância magnética convencional. Porém, certos tipos de quantificação exigem a aquisição softwares e de plataformas computacionais de alto custo, além de mão de obra especializada com conhecimento técnico em computação para operar em ambientes não intuitivos. Neste cenário o objetivo deste trabalho foi a implementação de um software para análise de transferência de magnetização em imagens de ressonância magnética nuclear que funcionasse na plataforma IBM-PC e em sistemas operacionais livres como GNU/Linux. Com este intuito foi elaborado um algoritmo para leitura de imagens codificadas no padrão DICOM 3.0, um algoritmo para a construção dos mapas de Razão de Transferência de Magnetização do volume adquirido e um visualizador com interface amigável para a segmentação e análise dos resultados. Ao final, software possibilitou a abertura da imagem DICOM. Também construiu de maneira eficiente, os mapas de diferença de porcentagem entre as imagens sem e com o pulso de transferência de magnetização (MTR), possibilitando, inclusive, correções de artefatos de movimentos, quando pouco intensos. Permitiu o delineamento de regiões de interesse irregular, com boa visibilidade dos resultados. Como controle padrão, os resultados foram comparados com o conjunto de ferramentas da Universidade McGill (Brain Imaging Center, McGuill University, Montreal, Quebec, Canadá), amplamente testado em artigos publicados.
Title in English
Development of software for quantitative image processing in magnetic resonance
Keywords in English
DICOM
image processing
magnetic resonance
Magnetization Transfer
medical image
software development
Abstract in English
The use of quantitative analysis in medical radiology has been of great value in the detection of not accessible alterations in the simple visual analysis, said qualitative, for being very subtle, or for not being present in conventional magnetic resonance image techniques. However, certain types of quantification demand the acquisition of high cost softwares and computational platforms, beyond specialized workmanship, with technical knowledge in computation, to operate in non intuitive environments. In this scenery the objective of this work was the implementation of a software for analysis of transference of magneti zation in nuclear magnetic resonance images that works in IBM-PC platform and free operational systems as GNU/Linux. So, an algorithm for reading of standard DICOM 3.0 codified images was elaborated, an algorithm for the construction of Magnetization Transfer Ratio maps of acquired volume, and a visualizer with friendly interface for segmentation and analysis of the results. Finally the software made the opening of DICOM image possible. It also generated in efficient way the maps of percentage difference among the images without and with the pulse of magnetization transfer (MT), also making devices of movement corrections possible, when they are not very intense. It allowed the delineation of regions of irregular interest, with good visibility of the results. As standard control, the results were compared with the set of tools of the McGill University (Brain Imaging Center, McGuill University, Montreal, Quebec, Canada), widely tested in published articles. The elaborated program took care of the considered objectives.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
final.pdf (3.79 Mbytes)
Publishing Date
2008-02-01
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.