Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.17.2017.tde-30032017-155442
Document
Auteur
Nom complet
Paula Duarte Correia
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2016
Directeur
Jury
Elias Júnior, Jorge (Président)
Ghilardi Netto, Thomaz
Marques, Paulo Mazzoncini de Azevedo
Titre en portugais
Estimativa de dose efetiva de radiação recebida por pacientes submetidos a exames de tomografia computadorizada e proposta para registro de dose por paciente em sistema de informação de radiologia
Mots-clés en portugais
CTDI
DICOM
Registro de dose
Tomografia Computadorizada
Resumé en portugais
A necessidade de estimar a dose efetiva de radiação recebida pelos pacientes em exames de tomografia computadorizada (TC) é muito discutida atualmente devido ao fato de que este exame está entre aqueles que mais depositam dose em pacientes submetidos a exames radiológicos. O objetivo deste trabalho foi implementar um método de estimativa de dose efetiva em exames de TC baseado em evidências bem estabelecidas e em informações contidas nas imagens. Após dosimetria realizada no equipamento de TC, mapeamento dos protocolos e definição dos fatores de correção a serem utilizados, uma rotina de processamento dos dados foi criada para conversão da informação do cabeçalho DICOM da imagem radiológica em dose efetiva estimada, de modo que as informações levantadas poderão ser disponibilizadas, em registro no sistema de informação de radiologia do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo - HCFMRP/USP, aos médicos e profissionais de saúde envolvidos.
Titre en anglais
Effective dose estimate received by patients undergoing computed tomography scans and proposal to dose record per patient in a radiology information system
Mots-clés en anglais
CTDI
DICOM
Registro de dose
Tomografia Computadorizada
Resumé en anglais
Computed tomography scan is the procedure that most deposits radiation dose in patients undergoing radiologic examinations. That is the reason why the need to record the dose received is currently discussed. The aim of this study was to implement an method to estimate effective dose received in CT scans based on well-established evidences and information contained in images. After performing dosimetry in CT equipment, mapped protocols and define correction factors, a data processing routine was created for conversion of DICOM header information in estimated effective dose, so that the information raised could be avalable in Hospital's radiology information system for doctors and health professionals involved.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2017-04-04
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.