Disertación de Maestría
DOI
https://doi.org/10.11606/D.17.2017.tde-30032017-135743
Documento
Autor
Nombre completo
Aline Aparecida Simsic
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2016
Director
Tribunal
Martinez, Jose Antonio Baddini (Presidente)
Regueiro, Eloisa Maria Gatti
Miranda, Carlos Henrique
Título en portugués
Tradução e validação da escala Dyspnoea-12 para o português falado no Brasil em pacientes com DPOC e hipertensão pulmonar
Palabras clave en portugués
Dispneia
DPOC
Hipertensão Pulmonar
Resumen en portugués
Objetivo: Traduzir e adaptar para o português falado no Brasil a escala Dyspnoea-12. Fornecer dados de validação da escala para pacientes com DPOC e hipertensão pulmonar (HP). Métodos: A versão em inglês da escala Dyspnoea-12 sofreu processo clássico de tradução, até obtenção de versão definitiva em português denominada Dispneia-12-Pt. A escala Dispneia-12-Pt foi aplicada a 51 pacientes com DPOC (33 homens; idade: 66,4±8,1 anos; VEF1: 48,7±17,2%) e 15 com HP de diferentes etiologias (12 mulheres; idade: 45,8±12,7 anos; pressão sistólica da artéria pulmonar: 88±33,2 mmHg). Os voluntários responderam a escala de dispneia do Medical Research Council(MRC), o índice de dispneia basal (IDB), a escala hospitalar de ansiedade e depressão, questionário respiratório de Saint George (QRSG), avaliação funcional respiratória e teste da caminhada dos seis minutos (TC6min). Sessenta voluntários responderam a escala uma segunda vez, duas semanas após a primeira avaliação. Resultados: No grupo DPOC a escala Dispneia-12-Pt apresentou correlações significantes com as escalas MRC (r=0,4641; p=0,0006), IDB (r=0,515; p <0,0001), QRSG (r=0,8113; p<0,0001), ansiedade (r=0,4714; p=0,0005), depressão (0,4139; p=0,0025) e distância percorrida no TC6min (r=0,3293; p=0,0255). No grupo com HP a escala mostrou correlações significantes com as escalas MRC (r=0,5774; p=0,0242), QRSG (r=0,6907; p=0,0044), distância percorrida no TC6min (r=0,7193; p=0,0025) e difusão do monóxido de carbono (r=0,564; p=0,0447). O alfa de Cronbach para os voluntários analisados em um único grupo foi 0,927 e o coeficiente de correlação intraclasse 0,8456. Conclusões: A escala Dispneia-12-Pt apresenta propriedades biométricas aceitáveis e pode ser empregada em pacientes brasileiros com dispneia de diferentes etiologias.
Título en inglés
Translation and validation of Dyspnoea -12 scale for the Portuguese spoken in Brazil in patients with COPD and pulmonary hypertension
Palabras clave en inglés
COPD
Dyspnea
Pulmonary hypertension
Resumen en inglés
Objective: To translate and to adapt for the Portuguese spoken in Brazil the scale Dyspnoea-12. To obtain validation data, regarding the use of this scale in patients with COPD and pulmonary hypertension (PH). Methods: The English version of the scale Dyspnoea-12 received a formal translation process and the final version was called Dispneia-12-Pt. The latter was applied to 51 COPD patients (33 men; age: 66.4±8.1 years; FEV1: 48.7±17.2 % pred) and 15 subjects with PH from different etiologies (12 women; age: 45.8±12.7 years; systolic pulmonary arterial pressure: 88±33.2 mmHg). The volunteers also answered the Medical Research Council dyspnea scale (MRC), the basal dyspnea index (DBI), the hospital scale of anxiety and depression, the Saint George Respiratory Questionnaire (SGRQ), respiratory functional evaluation and the six minute walk test (6 MWT). Sixty volunteers also answered the Dispneia-12-Pt scale about two weeks after the first evaluation. Results: In the COPD group the Dispneia-12-Br showed significant correlations with the scales MRC (r=0.4641; p=0.0006), BDI (0.515; p<0.0001), SGRQ (r=0.8113; p<0.0001), anxiety (r=0.4714; p=0.0005), depression (0.4139; p=0.0025) and walked distance in the 6 MWT (r=0.3293; p= 0.0255). In the HP group the scale showed significant correlations with the scales MRC (r=0.5774; p=0.0005), SGRQ (r=0.6907; p=0.0044), walked distance in the 6 MWT (0.7193; p=0.0025) and carbon dioxide diffusion capacity (r=0.564; p=0.0447). Cronbach´s alpha calculated for all volunteers evaluated as a whole was 0.927 while the intraclass correlation coefficient was 0.8456. Conclusions: The Dispneia-12-Pt exhibits acceptable biometric properties and may be used as a tool in Brazilian patients with dyspnea of different etiologies.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.