• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.17.2001.tde-06062002-092918
Documento
Autor
Nome completo
Danielle Malta Lima
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
Ribeirão Preto, 2001
Orientador
Banca examinadora
Fonseca, Benedito Antonio Lopes da (Presidente)
Figueiredo, José Fernando de Castro
Netto, Antonio Ruffino
Título em português
Aplicação da reação em Cadeia da Polimerase (PCR) para identificação do Mycobacterium tuberculosis em pacientes com suspeita de tuberculose pleural.
Palavras-chave em português
diagnóstico
tuberculose pleural
Resumo em português
O presente estudo tem como principal objetivo o emprego da reação em cadeia da polimerase (PCR) na elucidação da etiologia dos derrames pleurais dos pacientes com suspeita de pleurite tuberculosa, comparando-o com as técnicas diagnósticas disponíveis na atualidade. O diagnóstico da tuberculose pleural costuma ser feito por meio dos dados clínicos e radiológicos, teste tuberculínico, exames bioquímicos, microbiológicos, e citológicos do líquido pleural e da histopatologia de fragmento de pleura obtido por punção-biópsia. Ainda assim estes métodos apresentam muitas limitações, dentre as quais a baixa sensibilidade e o longo período necessário para a confirmação do diagnóstico. Estudamos 58 amostras de 45 pacientes. Destes, 16 pacientes tiveram diagnóstico clínico ou laboratorial confirmado de tuberculose, totalizando 22 amostras. Consideramos como caso de tuberculose todos os pacientes com baciloscopia, cultura ou histopatológico positivos no líquido pleural ou outro material biológico, ou que tenham apresentado melhora clínica após a introdução do tratamento empírico. Das 22 amostras com o diagnóstico de tuberculose, a PCR foi positiva em 6 amostras de 6 pacientes. A reação foi positiva em 1 amostra de um paciente em que o diagnóstico de tuberculose foi descartado. A sensibilidade, especificidade e os valores preditivo positivo e negativo nos 16 pacientes com diagnóstico de tuberculose foram 31,3%, 96,6%, 83% e 71% respectivamente. A PCR, apesar de ter apresentado uma baixa sensibilidade, demonstrou uma especificidade ótima em relação aos métodos convencionais. Está técnica pode ter utilidade como método complementar às técnicas disponíveis, na tentativa de obter um diagnóstico mais precoce e preciso nos casos de tuberculose pleural.
Título em inglês
Application of the Polymerase Chain Reaction (PCR) for identification of the Mycobacterium tuberculosis in patients with suspicion pleural tuberculosis.
Palavras-chave em inglês
Mycobacterium tuberculosis
diagnosis
pleural fluid
polymerase chain reaction
tuberculosis pleuritis
Resumo em inglês
The present study evaluates the use of the polimerase chain reaction (PCR) to confirm the etiology of pleural effusions in patients with suspicion of pleural tuberculosis, comparing it to the current available techniques. The diagnosis of pleural tuberculosis is made through the combination of clinical data, radiologic findings, biochemical, microbiological and cytological examination of the pleural fluid and by the pathology of pleural fragment obtained by biopsy. However, these methods present a lot of limitations, including a low sensitivity and a long incubation period to confirm the diagnosis by culture. We studied 58 samples of 45 patients with pleural effusion. Of these, 16 patients had clinical diagnosis or confirmed by laboratory, in a total of 22 samples. We defined as case of tuberculosis all patients with culture or positive pathology in the fluid pleural or other biological material and those with clinical improvement after empirical treatment. Of the 22 samples with the tuberculosis diagnosis PCR was positive in 6 samples of 6 patients. The reaction was positive in a sample of a patient whose diagnosis of tuberculosis was later discarded. The sensitivity, specificity, positive predictive value and negative predictive value in the 16 patients with tuberculosis diagnosis were 31,3%, 96,6%, 83% and 71% respectively. In spite of having presented a low sensitivity, PCR specificity was greater than the conventional methods. This technique can be useful as an additional method to the available techniques, in the attempt of obtaining a more precocious and precise diagnosis in the cases of pleural tuberculosis.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
00-Capa_Tese_Final.pdf (40.69 Kbytes)
01-Apresentacao.pdf (26.00 Kbytes)
02-Introducao.pdf (57.56 Kbytes)
03-Objetivos.pdf (31.62 Kbytes)
05-Resultados.pdf (56.30 Kbytes)
06-Discussao.pdf (39.12 Kbytes)
07-Conclusoes.pdf (18.01 Kbytes)
Data de Publicação
2002-06-21
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.