• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.17.2018.tde-23072018-102108
Document
Auteur
Nom complet
Darlan da Silva Bazilio
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2018
Directeur
Jury
Machado, Benedito Honório (Président)
Correa, Fernando Morgan de Aguiar
Cravo, Sergio Luiz Domingues
Salgado, Helio Cesar
Titre en portugais
Avaliação de parâmetros cardiovasculares e respiratórios durante o ciclo sono-vigília de ratos submetidos à hipóxia crônica intermitente
Mots-clés en portugais
Alterações cardiovasculares e respiratórias
Ciclo sono-vigília
Hipóxia crônica intermitente
Inspirações profundas
Resumé en portugais
A hipóxia crônica intermitente (HCI) é um modelo experimental no qual o quimiorreflexo é ativado a cada episódio de hipóxia, assim como em alguns casos de apneia obstrutiva do sono. A HCI promove aumento da atividade simpática, hipertensão e alterações no acoplamento simpático-respiratório no tronco encefálico. No presente trabalho estudamos os parâmetros cardiorrespiratórios concomitantemente com o ciclo sono-vigília em uma janela temporal de 3 horas no período do dia em que esses registros são feitos no nosso laboratório. Foram também registradas ao longo deste período as respostas cardiovasculares associadas a inspirações profundas (IPs) que acontecem normalmente nos ratos. Ratos Wistar (~ 250 g) foram divididos nos grupos HCI (n = 12) e controle (CTL) (n = 12). Os animais foram submetidos à cirurgia de implantação de eletrodos no crânio e nos músculos cervicais para obtenção de registros eletrocorticográficos (ECoG) e eletromiográficos (EMG), respectivamente, para determinarmos as fases do ciclo sono-vigília (vigília, sono NREM (non-rapid eye movement) e sono REM (rapid eye movement)). Um grupo de animais CTL (n=5) e outro de animais HCI (n=6) tiveram também eletrodos implantados nos músculos diafragma (DIA) e abdominal oblíquo (ABD) para registros da atividade muscular respiratória. Após 48 horas, o grupo HCI foi exposto a um protocolo de hipóxia intermitente durante 10 dias (6% de O2 por 40 s, a cada 9 min, 8 h/d), enquanto o grupo CTL foi mantido em normoxia (20,8% de O2) pelo mesmo período. No último dia do protocolo, os ratos tiveram uma artéria femoral canulada para registros de pressão arterial (PA). No dia seguinte, ECoG, EMG e a PA foram registrados por 3 horas para análise da latência para o sono, o tempo total em cada uma das fases do ciclo sonovigília, o número e a duração dos episódios de sono REM e os parâmetros cardiovasculares pressão arterial sistólica (PAS), pressão arterial diastólica (PAD), pressão arterial média (PAM) e frequência cardíaca (FC) nas diferentes fases do ciclo. Os parâmetros respiratórios foram registrados por 2 horas para análise de frequência respiratória (fR), volume corrente (VT) e volume minuto (VE) nas diferentes fases do ciclo sono-vigília. Os animais dos grupos utilizados para avaliação da atividade respiratória muscular foram registrados por 2 horas. O protocolo de 10 dias de HCIpromoveu alterações significativas apenas na duração dos episódios de sono REM nos ratos HCI. Entretanto, os animais do grupo HCI apresentaram níveis médios mais elevados de PAS (145,0 ± 1,8 vs 129,3 ± 2,2 mmHg), PAD (104,1 ± 1,7 vs 91,4 ± 1,8 mmHg), PAM (121 ± 9 vs 107,7 ± 1,9 mmHg) e FC (387, ± 5,4 vs 363,5 ± 8,7 bpm) no período de 3 horas de registro, sendo estes aumentos igualmente observados em todas as fases do ciclo sono-vigília. A HCI também promoveu aumento significativo de VT durante os sonos NREM (6,6 ± 0,2 vs 5,8 ± 0,2 mL/kg) e REM (6,4 ± 0,2 vs 5,3 ± 0,2 mL/kg), porém este parâmetro não foi significativamente diferente durante a vigília nos animais HCI em relação aos animais CTL. Ambos os grupos apresentaram expirações ativas apenas durante a vigília, porém estas foram muito mais frequentes nos animais HCI. Além disso, nos animais HCI as respostas de queda da PAM (-18 ± 0,8 vs -14 ± 0,6 mmHg) e aumento da FC (28,4 ± 1,8 vs 21,8 ± 1,1 bpm) associadas às IPs apresentaram maiores magnitudes em relação aos animais CTL, embora o intervalo temporal entre as IPs não tenha se alterado. Esses achados indicam que a HCI aplicada durante 10 dias promove alterações significativas na duração dos episódios de sono REM, aumento da PA e FC em todas as fases do ciclo sono-vigília, aumento do VT durante o sono, aumento da ocorrência de expirações ativas durante a vigília e aumento das respostas hemodinâmicas associadas às IPs. Portanto, as alterações cardiovasculares observadas após a HCI são decorrentes dos episódios repetidos de hipóxia que acontecem ao longo desse protocolo, mas não parecem ser dependentes de alterações no ciclo sono-vigília, pois ainda que a duração dos episódios de sono REM tenha sido maior nos ratos HCI, os parâmetros cardiovasculares se apresentaram igualmente elevados em todas as fases do ciclo sono-vigília desses animais.
Titre en anglais
Evaluation of cardiovascular and respiratory parameters during the sleep-wake cycle of rats submitted to chronic intermittent hypoxia
Mots-clés en anglais
Cardiovascular and respiratory alterations
Chronic intermittent hypoxia
Deep breaths
Sleep-wake cycle
Resumé en anglais
Chronic intermittent hypoxia (CIH) is an experimental model in which the chemoreflex is activated at each episode of hypoxia, as observed in some cases of obstructive sleep apnea. CIH induces increased sympathetic activity, hypertension, and changes in the sympathetic-respiratory coupling in the brainstem. In the present study, we recorded cardiorespiratory parameters concomitantly with the sleep-wake cycle during a 3-hour time window which corresponds to the period of the day in which these recordings are collected in our laboratory. During this period, we also studied the cardiovascular responses associated with the normally occurring deep breaths (DBs) in rats. Male Wistar rats (~ 250 g) were divided into CIH (n = 12) and control (CTL) groups (n = 12). Animals underwent implantation of electrodes in the skull and in the cervical muscles for electrocorticographic (ECoG) and electromyographic (EMG) recordings, respectively, to determine the phases of the sleep-wake cycle (wakefulness, NREM sleep and REM sleep). A group of CTL animals (n=5) and another of HCI animals (n=6) had electrodes implanted also in the diaphragm (DIA) and oblique abdominal muscle (ABD) for recordings of respiratory muscle activity. After 48 hours, the CIH group was exposed to an intermittent hypoxia protocol for 10 days (6% O2 for 40 s, every 9 min, 8 h/d), while the CTL group was maintained in normoxia (20.8 % of O2) for the same period. On the last day of the protocol, rats had a femoral artery cannulated for blood pressure (BP) recordings. On the following day, ECoG, EMG and BP were recorded for 3 hours for analysis of time for sleep onset, total time in each phase of the sleep-wake cycle, number and duration of REM sleep episodes, and the cardiovascular parameters systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP) and heart rate (HR) in the different phases of the cycle. The respiratory parameters were recorded for 2 hours for analysis of ventilatory frequency (fR), tidal volume (VT) and minute volume (VE) in the different phases of the sleep-wake cycle. The groups of animals used for analysis of respiratory muscle activity were recorded for only 2 hours. CIH promoted significant alterations only in the duration of REM episodes. However, animals from CIH group had higher average levels of SBP (145,0 ± 1,8 vs 129,3 ± 2,2 mmHg), DBP (104,1 ± 1,7 vs 91,4 ± 1,8mmHg), MAP (121 ± 9 vs 107,7 ± 1,9 mmHg) e HR (387, ± 5,4 vs 363,5 ± 8,7 bpm) in the 3-hour recording period. These increases were also observed in all phases of the sleep-wake cycle. CIH also promoted a significant increase in VT during NREM (6,6 ± 0,2 vs 5,8 ± 0,2 mL/kg) and REM (6,4 ± 0,2 vs 5,3 ± 0,2 mL/kg), although this parameter was not significantly different during wakefulness in CIH animals compared to CTL animals. Both groups presented active expiration only during wakefulness, however it was much more frequent in HCI rats. In addition, in CIH animals, the fall in MAP (-18 ± 0,8 vs -14 ± 0,6 mmHg) and the increase in HR (28,4 ± 1,8 vs 21,8 ± 1,1 bpm) associated with DBs presented higher magnitudes in relation to CTL animals, although the time interval between DBs did not change. These findings indicate that CIH for 10 days promotes longer REM episodes, increased BP and HR in all phases of the cycle, increased VT during sleep, increased active expiration occurrence and higher magnitudes of the hemodynamic responses associated with DBs. Therefore, the cardiovascular alterations observed after CIH are due to the intermittent hypoxia episodes that occur throughout this protocol, but do not seem to be related to changes in the sleep-wake cycle, for although the duration of REM episodes was longer, the cardiovascular parameters were equally increased in all phases of the sleep-wake cycle.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2018-07-23
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.