• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.16.2018.tde-22062017-155747
Document
Auteur
Nom complet
Daniela Cardoso Laudares Pereira
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2017
Directeur
Jury
Scarazzato, Paulo Sergio (Président)
Amorim, Cláudia Naves David
Gonçalves, Joana Carla Soares
Moura, Norberto Corrêa da Silva
Pereira, Fernando Oscar Ruttkay
Titre en portugais
Iluminação natural em edifícios de escritórios: metodologia para avaliação do desempenho luminoso
Mots-clés en portugais
Análise de desempenho
Edifícios de escritório
Iluminação natural
Simulação computacional
Resumé en portugais
Esta tese parte da hipótese de que nem todos os edifícios de escritório com certificação ambiental na cidade de São Paulo, construídos entre os anos 2000 a 2016, atendem de modo satisfatório as condições de iluminação natural, segundo as recomendações hoje em vigor. Esses edifícios contemporâneos possuem grandes áreas envidraçadas em suas fachadas, sem proteção solar, que causam problemas de conforto térmico e luminoso. Para evitar o ofuscamento, os usuários acionam proteções solares internas como telas e persianas, o que acaba por impedir ou diminuir o acesso à luz natural. A pesquisa realizada fez um levantamento dos padrões construtivos prevalecentes em 28 edifícios de escritório que se enquadram na especificação descrita acima para verificar questões como: a profundidade da planta, transmissão luminosa dos vidros, WWR (Wall Window Ratio), entre outras. Os dados encontrados serviram para a elaboração de modelos referenciais, usados em simulações computacionais, com o objetivo de verificar a influência de variáveis arquitetônicas no desempenho da iluminação natural. As simulações foram realizadas no plug-in Diva do programa Rhinoceros 3D, que simula a iluminação natural de forma integrada com os softwares Radiance/DAYSIM, já validados pela comunidade científica internacional. O tratamento dos dados foi feito através de um método inédito de avaliação do desempenho luminoso e os resultados obtidos mostraram que 60% dos cenários analisados foram reprovados. Esta tese propõe uma metodologia de avaliação do desempenho luminoso de edifícios de escritório que considere de modo integrado a disponibilidade de luz natural, o conforto visual e o consumo de energia.
Titre en anglais
Daylighting in office buildings: a methodology for evaluating luminous performance
Mots-clés en anglais
Computational simulation
Daylighting
Office buildings
Performance analysis
Resumé en anglais
This thesis is based on the hypothesis that not all office buildings with environmental certification in the city of São Paulo, constructed between 2000 and 2016, meet satisfactorily the conditions of daylighting, according to the recommendations currently in force. These contemporary offices have large glass areas without sun protection in their facades, causing problems of thermal and luminous comfort. In order to avoid glare, users employ indoor shading devices such as rollers and blinds, which ultimately prevent or reduce access to daylight. This research has carried out a survey on the prevailing constructive patterns of 28 office buildings that follow the specifications described above, to verify issues such as plan depth, light transmission of glasses, WWR (Wall Window Ratio), among others. The collected data were used to elaborate reference models used in computational simulations, aiming at verifying the influence of architectural variables on the performance of daylighting. The simulations were carried out with the Diva plug-in for Rhinoceros 3D program, which simulates daylighting, integrated with software Radiance/DAYSIM, already validated by the international scientific community. The data treatment was carried out through an innovative method for evaluating luminous performance, and the obtained results showed that 60% of the analyzed scenarios were disapproved. This thesis proposes that the methodology for evaluating the luminous performance of office buildings should consider the availability of daylight, visual comfort, and energy consumption in an integrated way.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2018-04-17
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.