• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.16.2007.tde-17052010-113943
Document
Author
Full name
Gisele Saveriano De Benedetto
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2007
Supervisor
Committee
Romero, Marcelo de Andrade (President)
Akutsu, Maria
Duarte, Denise Helena Silva
Title in Portuguese
Avaliação da aplicação do modo misto na redução da carga térmica em edifícios de escritórios nas cidades de São Paulo e Rio de Janeiro
Keywords in Portuguese
Arquitetura
Conforto térmico
Desempenho energético
Desempenho térmico
Eficiência energética
Modo misto
Simulação computacional
Abstract in Portuguese
Diante das atuais questões ambientais, o uso eficiente da energia é uma premissa em todos os setores de atividades. Sabe-se que as edificações são grandes consumidores de energia e boa parcela desse consumo se dá em sistemas de condicionamento artificial. São três os principais fatores que atuam no balanço térmico e influenciam esse consumo: arquitetura, ocupação e clima. A arquitetura atua como intermediária nesse balanço térmico, podendo ajudar ou prejudicar as condições internas. Este trabalho estuda o desempenho térmico e energético dos edifícios de escritórios em São Paulo e Rio de Janeiro, cidades que apresentam condições extremas de calor durante o verão e até em outras estações do ano. O tipo de ocupação e a atividade realizada em edifícios de escritórios nos dias de hoje criam, por si sós, cargas térmicas elevadas que dificultam ainda mais a obtenção de conforto. Este trabalho parte do pressuposto de que existem soluções arquitetônicas de edifícios de escritórios na cidade de São Paulo capazes de garantir conforto térmico aos usuários durante parte do período de ocupação sem uso de condicionamento artificial, porém acreditar que é possível obter conforto apenas com sistemas passivos durante o ano todo nos atuais edifícios de escritórios das cidades de São Paulo e Rio de Janeiro é ilusão. Diante desse desafio, o sistema de modo misto de condicionamento ambiental une as vantagens do sistema ativo às do passivo, operando com sistemas naturais sempre que possível, reduzindo o consumo de energia e acionando o sistema ativo em situações fora das condições de conforto. Utilizar o sistema de modo misto não significa abrir as janelas de qualquer edifício no inverno. O edifício deve estar preparado para o sistema desde as etapas de projeto. Com base nesse pensamento, a pesquisa analisa o desempenho térmico e energético de três tipologias arquitetônicas operando com o sistema de modo misto em São Paulo e investiga o desempenho das mesmas tipologias sob as condições climáticas da cidade do Rio de Janeiro. As avaliações de desempenho térmico e energético das tipologias são feitas por meio de análises e comparações de resultados de simulações computacionais com o programa TAS (9.0.7 maio, 2005).
Title in English
Evaluation of mixed-mode application for thermal load reduction in office buildings at the cities of São Paulo and Rio de Janeiro
Keywords in English
Architecture
Computer simulation
Energy efficiency
Mixed mode
Thermal comfort
Thermal energy
Thermal performance
Abstract in English
Considering current environmental issues, all sectors of activities are premised on the efficient use of energy. Its known that constructions are great energy consumers and part of this consumption is given by artificial conditioning systems. Therere three main factors in thermal balance that influences this consumption: architecture, occupation and climate. The architecture acts as intermediate in this thermal balance, being able to help or harm internal conditions. This research treats office building thermal and energy performance in São Paulo and Rio de Janeiro, cities with high temperatures not only during the summer but also in other seasons. Nowadays, offices occupation and activity are themselves great heat producers, what makes thermal comfort even more difficult to achieve. This project considers that there are office building design solutions able to produce thermal environmental conditions acceptable to a majority of occupants, without air-conditioning system, during part of the working period, in São Paulo. However, believing the possibility of achieving comfort conditions in actual office buildings, only with passive cooling strategies, during all year, in the cities of São Paulo and Rio de Janeiro, is an illusion. Facing this challenge, mixed mode system combines the best of air-conditioning and natural ventilation, operating with natural strategies whenever its possible, reducing energy consumption and using the air-conditioning system only when thermal environmental conditions are not acceptable. Mixed mode operation does not mean to open any building windows during the winter. The building must have been designed for the mixed mode system since its first projects. This research is based on this thought and thermal analysis and energy performance of three architectural design buildings operating with mixed mode system in São Paulo and investigates the performance of these building types under climate conditions of Rio de Janeiro city. The thermal and energy performance evaluations of the building types are based on the analysis and comparison of computer simulations results, with the software TAS (9.0.7 May, 2005).
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2010-05-31
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.