• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.14.2009.tde-15012010-132654
Document
Auteur
Nom complet
José Felipe da Silva Farias
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2009
Directeur
Jury
Pereira Filho, Augusto Jose (Président)
Barros, Mario Thadeu Leme de
Massambani, Oswaldo
Titre en portugais
Previsão de chuva a curtíssimo prazo na área de abrangência do radar meteorológico de São Paulo
Mots-clés en portugais
enchentes
hidrometeorologia
Previsão de chuva à curtíssimo prazo
Resumé en portugais
A avaliação da previsão de chuva a curtíssimo prazo com até 3 horas de antecedência na área de cobertura do RSP para diferentes tipos de sistemas precipitantes, principalmente os associados às enchentes e deslizamentos na RMSP, foi realizada por meio de um modelo advectivo a partir do campo de vento 2D médio e da velocidade dos campos das taxas de precipitação estimados com o radar e um Esquema Numérico de Terceira Ordem Corrente Acima (ENTOCA). O ENTOCA utiliza um vetor com deslocamento mantido constante. O desempenho da previsão para precipitação acumulada num determinado intervalo de tempo foi avaliado pelo Índice de Sucesso Crítico (CSI), Probabilidade de Detecção (POD) e Razão de Falsos Alarmes (FAR). Quantitativamente, a acurácia da previsão foi avaliada por meio do Erro Quadrático Médio (EQM). O coeficiente de correlação mostrou que a qualidade da previsão decresce ao longo do tempo, com maior previsibilidade para os sistemas estratiformes do que para os convectivos. O ENTOCA não considera a evolução espaço-temporal dos sistemas precipitantes durante a extrapolação do campo das taxas de precipitação. Em geral, constatou-se uma subestimativa da precipitação acumulada. As previsões também apresentaram maior desempenho para até 90 minutos e menor, a partir de 120 minutos de extrapolação. O desempenho médio da previsão pelo índice CSI para o limiar de 0.2 mm ao final de 60 minutos de precipitação acumulada foi: FFs (77%), Lis (67,5%), BDs (58%), CIs (56,4%) e BMs (47%). Em geral, a partir de 90 minutos de advecção (sistemas convectivos) e 120 minutos (sistemas estratiformes), o desempenho da previsão diminui exponencialmente.
Titre en anglais
Rainfall short-term forecast in the surveillance area of São Paulo weather radar.
Mots-clés en anglais
floods
hidrometeorology
rainfall short-term forecast
Resumé en anglais
The evaluation of the rainfall short-term forecast up to 3 hours in advance within the surveillance area of São Paulo weather radar (RSP) for different types of precipitating systems, mainly the are associated to floods and landslides in Metropolitan Area of São Paulo (RMSP), was carried out with an 2D wind advective scheme and rainfall rates estimated with the RSP. The third-order upstream numerical scheme (ENTOCA) was used with a uniform wind vector. The rainfall forecast skill for a given time interval was evaluated by the Critical Success Index (CSI), Probability of Detention (POD) and False Alarm Rate (FAR). Quantitatively, the accuracy of the forecast was evaluated with the mean-square error (mse). The correlation coefficient showed that the quality of the forecast decrease with time, with better skill for the stratiform systems than for convective ones, given that the ENTOCA do not take into account spatial-temporal evolution of the rainfall systems. In general, the precipitation accumulation was underestimated. The forecasts had better skill up to 90 minutes. The average skill based on CSI for the thresholds of 0.2 mm at 60 minutes the precipitation accumulation are: FFs (77%), Lis (67,5%), BDs (58%), CIs (56,4%) and BMs (47%). In general, from 90 minutes of advection (convective systems) and 120 minutes (stratiform systems), the skill of the forecast decreases.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2010-09-23
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.