Master's Dissertation
DOI
https://doi.org/10.11606/D.14.2009.tde-15012010-132654
Document
Author
Full name
José Felipe da Silva Farias
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2009
Supervisor
Committee
Pereira Filho, Augusto Jose (President)
Barros, Mario Thadeu Leme de
Massambani, Oswaldo
Title in Portuguese
Previsão de chuva a curtíssimo prazo na área de abrangência do radar meteorológico de São Paulo
Keywords in Portuguese
enchentes
hidrometeorologia
Previsão de chuva à curtíssimo prazo
Abstract in Portuguese
A avaliação da previsão de chuva a curtíssimo prazo com até 3 horas de antecedência na área de cobertura do RSP para diferentes tipos de sistemas precipitantes, principalmente os associados às enchentes e deslizamentos na RMSP, foi realizada por meio de um modelo advectivo a partir do campo de vento 2D médio e da velocidade dos campos das taxas de precipitação estimados com o radar e um Esquema Numérico de Terceira Ordem Corrente Acima (ENTOCA). O ENTOCA utiliza um vetor com deslocamento mantido constante. O desempenho da previsão para precipitação acumulada num determinado intervalo de tempo foi avaliado pelo Índice de Sucesso Crítico (CSI), Probabilidade de Detecção (POD) e Razão de Falsos Alarmes (FAR). Quantitativamente, a acurácia da previsão foi avaliada por meio do Erro Quadrático Médio (EQM). O coeficiente de correlação mostrou que a qualidade da previsão decresce ao longo do tempo, com maior previsibilidade para os sistemas estratiformes do que para os convectivos. O ENTOCA não considera a evolução espaço-temporal dos sistemas precipitantes durante a extrapolação do campo das taxas de precipitação. Em geral, constatou-se uma subestimativa da precipitação acumulada. As previsões também apresentaram maior desempenho para até 90 minutos e menor, a partir de 120 minutos de extrapolação. O desempenho médio da previsão pelo índice CSI para o limiar de 0.2 mm ao final de 60 minutos de precipitação acumulada foi: FFs (77%), Lis (67,5%), BDs (58%), CIs (56,4%) e BMs (47%). Em geral, a partir de 90 minutos de advecção (sistemas convectivos) e 120 minutos (sistemas estratiformes), o desempenho da previsão diminui exponencialmente.
Title in English
Rainfall short-term forecast in the surveillance area of São Paulo weather radar.
Keywords in English
floods
hidrometeorology
rainfall short-term forecast
Abstract in English
The evaluation of the rainfall short-term forecast up to 3 hours in advance within the surveillance area of São Paulo weather radar (RSP) for different types of precipitating systems, mainly the are associated to floods and landslides in Metropolitan Area of São Paulo (RMSP), was carried out with an 2D wind advective scheme and rainfall rates estimated with the RSP. The third-order upstream numerical scheme (ENTOCA) was used with a uniform wind vector. The rainfall forecast skill for a given time interval was evaluated by the Critical Success Index (CSI), Probability of Detention (POD) and False Alarm Rate (FAR). Quantitatively, the accuracy of the forecast was evaluated with the mean-square error (mse). The correlation coefficient showed that the quality of the forecast decrease with time, with better skill for the stratiform systems than for convective ones, given that the ENTOCA do not take into account spatial-temporal evolution of the rainfall systems. In general, the precipitation accumulation was underestimated. The forecasts had better skill up to 90 minutes. The average skill based on CSI for the thresholds of 0.2 mm at 60 minutes the precipitation accumulation are: FFs (77%), Lis (67,5%), BDs (58%), CIs (56,4%) and BMs (47%). In general, from 90 minutes of advection (convective systems) and 120 minutes (stratiform systems), the skill of the forecast decreases.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2010-09-23
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.