• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.14.2019.tde-28052018-150717
Documento
Autor
Nombre completo
Antonio Carlos de Siqueira Neto
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2015
Director
Tribunal
Elis, Vagner Roberto (Presidente)
Fachin, Sergio Junior da Silva
Gallas, Jose Domingos Faraco
Título en portugués
Utilização de métodos geoelétricos na caracterização de célula experimental no aterro de resíduos urbanos Delta A em Campinas - SP
Palabras clave en portugués
Aterro Sanitário
Célula Experimental.
Eletrorresistividade
Polarização induzida
Resumen en portugués
Os métodos de eletrorresistividade (ER) com a técnica de caminhamento elétrico (CE), método da polarização induzida (IP) e o método eletromagnético indutivo (EM) foram aplicados no aterro Delta A, localizado ao lado da rodovia dos Bandeirantes no município de Campinas (SP). Dentro do aterro há uma região de aproximadamente 5.200 m² denominada célula experimental, com impermeabilização de base por meio de geomembrana de PEAD (Polietileno de alta densidade) onde ocorre um monitoramento regular pelo Departamento de Geotecnia da UNICAMP. Esse projeto teve como objetivo principal verificar como o corpo de resíduos e a geomembrana são imageados com os métodos geofísicos, e se existe evidência de zonas de concentração de chorume e como seriam as imagens caso houvesse ruptura da geomembrana com vazamento. Na área foram executadas 6 linhas com extensão de 110 m e espaçamento de 12 m entre elas, utilizando arranjo dipolo-dipolo com espaçamento entre eletrodos de 4 m e 5 m e cabo de 10 e 20 m para as medidas de EM. Com os resultados apresentados podemos afirmar que o método que melhor forneceu informações sobre a célula experimental foi o de eletrorresistividade, pois identificou a camada resistiva (geomembrana) e nos permitiu comparar os dados com as simulações feitas em laboratório. No entanto, para uma melhor resolução dos dados de ER se faz necessário diminuir a distância entre os eletrodos, aumentando assim a acurácia do levantamento.
Título en inglés
Use of geoelectrical methods in the characterization of an experimental cell at the landfill of municipal waste Delta A in Campinas - SP.
Palabras clave en inglés
Electrical Resistivity
Experimental Cell
Induced Polarization
Landfill
Resumen en inglés
The methods of resistivity (ER) with the electrical profiling technique (EP), the method of induced polarization (IP) and the inductive electromagnetic method (EM) were applied to landfill Delta A, located next to the highway dos Bandeirantes in Campinas (SP). Within the landfill there is a region of approximately 5,200 m² called "experimental cell" with waterproofing base through HDPE (High Density Polyethylene) geomembrane which is regular monitoring by the UNICAMP Geotechnical Department. The main objective was to verify how the body of waste and the geomembrane are imaged with geophysical methods, and if there is evidence of leachate concentration areas and how the images would be if there was rupture of the geomembrane leaking. In the area were performed 6 lines with a length of 110 m and 12 m spacing between them using dipole-dipole array with electrode spacing of 4 m and 5 m and cable of 10 and 20 m for EM measures. With the results presented we can say that the method that best provided information on the experimental cell was the resistivity method, as identified resistive layer (geomembrane) and allowed us to compare the data with simulations in the laboratory. However, for better resolution of the ER data is needed to close the distance between the electrodes, thereby increasing the accuracy of the survey.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
versaocorrigida.pdf (3.49 Mbytes)
Fecha de Publicación
2019-01-22
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.