• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.11.2013.tde-17122013-121535
Document
Author
Full name
Leandro Maria Gimenez
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Piracicaba, 2013
Supervisor
Committee
Molin, Jose Paulo (President)
Calixto, Wesley Pacheco
Moraes, Sergio Oliveira
Rabello, Ladislau Marcelino
Silva, Alvaro Pires da
Title in Portuguese
Relação da condutividade elétrica aparente com algumas propriedades físico-hídricas e com a variabilidade espacial dos solos
Keywords in Portuguese
Camada
Estratificação
Geoelétrico
Método
Porosidade
Resistividade elétrica
Sondagem
Abstract in Portuguese
A variabilidade das propriedades físicas do solo apresenta impacto sobre o desempenho das atividades de produção agrícola. Métodos indiretos para obtenção de informações sobre as propriedades do solo com interesse agronômico são utilizados com o intuito de favorecer o uso de insumos de modo mais adequado. A condutividade elétrica aparente do solo (CEa) é influenciada por diversas propriedades, muitas delas interrelacionadas e com variabilidade em curta distância, sendo difícil a separação dos diversos fatores. As medidas de CEa são usualmente tomadas em superfície com arranjos de eletrodos para prospecção de um volume de solo proporcional à distância entre eles. Neste trabalho foi utilizada uma metodologia que permitiu identificar algumas das propriedades com maior impacto sobre a CEa, merecendo destaque aquelas relacionadas ao espaço poroso do solo. A caracterização detalhada da variação da CEa ao longo do perfil do solo e sua comparação com aquela obtida a partir da sondagem elétrica vertical permitiram identificar algumas limitações desta técnica. A presença de camadas com variação de diversas propriedades físicas e de umidade no perfil do solo alterou os valores observados em superfície. A relação entre a distância de separação dos eletrodos no arranjo com quatro pontas igualmente espaçadas, e a profundidade de prospecção, coeficiente k, oscilou entre 0,35 e 0,70 para os solos LVd, LAd e PVe avaliados. A sondagem elétrica empregada na caracterização de variabilidade espacial na horizontal e em profundidade em uma área com teores de argila oscilando entre 150 e 379 g kg-1 na camada 0 a 0,2 m e entre 225 e 326 g kg-1 na camada 0,6 a 0,8 m apresentou resultado satisfatório.
Title in English
Apparent electrical conductivity relationship with some physical properties and spatial variability in soils
Keywords in English
Electrical resistivity
Electrical sounding
Layer
Layering
Method
Porosity
Rooting zone
Surface geophysics
Survey
Abstract in English
The variability of soil physical properties has an impact on the performance of agricultural production activities. Indirect methods for obtaining information on the soil properties with agronomic interest are used to allow the use of inputs more appropriately. The apparent soil electrical conductivity ( ECa ) is influenced by several properties , many of them interrelated and presenting variability in short distances, being difficult to separate the various factors. ECa measures are usually taken in surface, using electrode arrangements for prospecting a soil volume proportional to the distance between them. In this work, a methodology was used that identified some of the properties with the greatest impact on the ECa, with emphasis to those related to soil porous space. The detailed characterization of the variation of ECw throughout the soil profile and its comparison with that obtained from the vertical electrical sounding was carried to identify certain limitations of this technique. The presence of several layers with varying physical properties and moisture in the soil profile changed values obtained from surface sounding. The relationship between the separation of the electrodes in the array with four points equally spaced, the Wenner array, and the depth of exploration, coefficient k, ranged between 0.35 and 0.70 for the soils LVd , LAd PVe and evaluated. A survey was done for the ECa characterization of spatial variability in the horizontal and along soil profile in an area with clay content ranging from 150 to 379 g kg - 1 in the layer from 0 to 0.2 m and between 225 and 326 g kg - 1 in layer 0, 6 to 0.8 m. The use of ECa for characterizing this variability showed satisfactory results.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2014-01-07
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.