• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.11.2019.tde-14052019-104849
Document
Auteur
Nom complet
Diego José de Sousa Pereira
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Piracicaba, 2019
Directeur
Jury
Frizzone, Jose Antonio (Président)
Camargo, Antonio Pires de
Coelho, Rubens Duarte
Rocha, Hermes Soares da
Titre en portugais
Contribuição ao protocolo de normatização de ensaios para a avaliação da sensibilidade de gotejadores à obstrução causada por partículas sólidas
Mots-clés en portugais
Deposição de partículas
Entupimento
Microirrigação
Qualidade da água
Resumé en portugais
A obstrução dos emissores é apontada como o principal problema da irrigação por gotejamento, sendo a obstrução por agentes físicos a mais observada. No mercado, existem diversos modelos de emissores, sendo que a sensibilidade à obstrução varia conforme a qualidade da água e a geometria interna do emissor. Nesse contexto, o desenvolvimento de uma metodologia de avaliação da susceptibilidade de emissores à obstrução é importante para a identificação de modelos de emissores menos sensíveis à obstrução. A norma ISO/DTR 21540 (em desenvolvimento) especifica métodos de laboratório e de campo para a avaliação da sensibilidade de gotejadores à obstrução causada por partículas sólidas. O objetivo dessa pesquisa foi identificar limitações e propor aprimoramentos na etapa de ensaios de laboratório da ISO/DTR 21540, visando melhorar a repetitividade dos resultados e contribuir para a obtenção de uma metodologia mais robusta e confiável. Além disso, para a compreensão dos processos de obstrução por partículas sólidas, buscou-se analisar as principais causas e regiões de deposição de partículas ao longo dos labirintos dos emissores. Foram avaliados dois modelos de emissores (Taldrip 0,55 L h-1 e Drip-Tech 1,55 L h-1). O material utilizado como agente causador de obstrução foi um composto de partículas sólidas preparadas a partir de solo natural conforme requisitos da norma ISO 11277. O ensaio de obstrução consistiu de quatro fases, com duração de 40 horas cada, em uma combinação entre faixas granulométricas (0-75, 75-125; 125-212 e 212-500 μm) e concentração de partículas (125, 250, 375 e 500 mg L-1), com o aumento do risco de obstrução a cada fase. Essa pesquisa permitiu identificar limitações e enunciar recomendações para melhoria do protocolo de ensaios em discussão na ISO/DTR 21540. O acúmulo de partículas com dimensões relativamente grande (> 125 μm) foi a principal causa de obstrução, reforçando a probabilidade de que a granulometria de partículas é um fator dominante nos processos de obstrução quando se usa esse protocolo de ensaios.
Titre en anglais
Contribution to a standardized test protocol for assessing the sensitivity of drippers to clogging due to solid particles
Mots-clés en anglais
Clogging
Microirrigation
Particle deposition
Water quality
Resumé en anglais
Clogging of emitters is pointed out as the main problem of drip irrigation, being the clogging by physical agents the most observed. In the market, there are several models of emitters, and the sensitivity to the clogging varies according to the water quality and the internal geometry of the emitter. In this context, the development of a methodology that evaluates the susceptibility of emitters to clogging is important, once that it can identify less sensitive emitter models to clogging. The standard ISO / DTR 21540 (under development) specifies laboratory and field methods for assessing the sensitivity of drippers to clogging caused by solid particles. The aim of this research was to identify limitations and propose improvements in the ISO / DTR 21540 laboratory test stage, in order to improve the repeatability of the results and contribute to a more robust and reliable methodology. In addition, to understand the solid particle clogging processes, were analyzed the main causes and regions of particle deposition along the labyrinths of the emitters. Two emitter models (Taldrip 0.55 L h-1 and Drip-Tech 1.55 L h-1) were evaluated. The material used as clogging agent was solid particles compound prepared from natural soil according to the ISO 11277 requirements. The clogging test consisted of four stages, lasting 40 hours each, in a combination of granulometric range (0-75, 75-125, 125-212 and 212-500 μm) and particle concentration (125, 250, 375 and 500 mg L-1), with higher risk of clogging at each stage. This research allowed to identify limitations and enunciate recommendations for improvement of the test protocol under discussion in ISO / DTR 21540. The accumulation of particles with relatively large dimensions (> 125 μm) was the main cause of clogging, reinforcing the probability that the grain size particle is a dominant factor in the clogging processes when using this test protocol.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2019-06-04
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.