Coeficiente de descarga em emissores de pivô central
Palabras clave en portugués
Equipamentos agrícolas
Hidráulica aplicada
Irrigação por pivô central - Dimensionamento.
Resumen en portugués
A crescente busca por tecnologias com melhor desempenho energético faz com que a engenharia da irrigação desenvolva emissores que apresentem coeficientes de descarga mais elevados. O presente trabalho teve como objetivo determinar os coeficientes de descarga dos emissores comerciais (Senninger, Nelson e Fabrimar), utilizados em sistema de irrigação pivô central, visando desenvolver equações de regressão para cálculo do Cd, de acordo com o diâmetro do bocal e a pressão de serviço dos emissores, assim como comparar o dimensionamento hidráulico destes sistemas de irrigação com base no Cd médio e no Cd específico de cada diâmetro de bocal. Os ensaios foram realizados no Laboratório de Irrigação do Departamento de Engenharia de Biossistemas da ESALQ, Universidade de São Paulo, seguindo o padrão de pressão utilizado na comercialização destes emissores (PSI). Foram avaliados 45 bocais Senninger, 42 bocais Nelson e 36 bocais Fabrimar, de diferentes diâmetros nominais, compreendidos entre 1/16 e 13/32 (1,59 e 10,32 mm), com três repetições, totalizando 369 bocais ensaiados. As pressões de operação variaram entre a faixa de 6 a 30 PSI (41,37 a 206,84 kPa), com intervalos de leituras a cada 2 PSI (13,79 kPa), totalizando 13 pressões analisadas por bocal. Foram ajustadas as curvas do coeficiente de descarga em função do diâmetro do bocal, para quatro pressões de operação 10, 15, 20, e 30 PSI (68,95, 103,42, 137,90 e 206,84 kPa). Utilizaram-se dois manômetros de precisão (analógico e digital) previamente calibrados em um manômetro de peso morto. As vazões foram obtidas utilizando-se três medidores eletromagnético-indutivos calibrados em recipiente volumétrico. O diâmetro dos bocais foi mensurado por meio de uma ampliação em projetor de perfil. Os resultados evidenciam que o coeficiente de descarga varia em função do diâmetro do bocal, da pressão de operação e do ângulo de convergência (fator construtivo). Nos ensaios conduzidos, obtiveram-se valores de Cd compreendidos na faixa de 0,88 a 0,98 para a faixa de emissores analisados. O coeficiente de uniformidade de distribuição não se diferenciou entre os sistemas hidráulicos dimensionados com Cd médio e especifico para cada diâmetro de bocal.
Título en inglés
Discharge coefficient for center pivot emitters
Palabras clave en inglés
Agricultural Equipment
Applied Hydraulic
Center pivot irrigation
Designing.
Resumen en inglés
The necessity for more energy efficient technologies makes the engineering of irrigation develop emitters with higher discharge coefficients. This study aimed to determine the discharge coefficients of commercial emitters (Senninger, Nelson and Fabrimar) used in center pivot irrigation system, in order to develop regression equations to calculate the Cd, of according to the diameter of the nozzle and pressure service of the emitters, and compare the hydraulic design of this irrigation system based on the average Cd and Cd specific nozzles for each nozzle diameter. The tests were carried out at the Irrigation Department of Biosystems Engineering, ESALQ, University of Sao Paulo, following the standards of the American unit system. It was evaluated a set of 45 Senninger nozzles, 42 Nelson nozzles and 36 Fabrimar nozzles, of different nominal diameters, ranging from 1/16" to 13/32" (1.59 and 10.32 mm) with three replications, totalizing 369 nozzles tested. The operation pressures ranged from 6 to 30 psi (41,37 a 206,84 kPa), at intervals of 2 psi (13,79 kPa), totalizing 13 pressures for nozzle. Curves were drawn for the discharge coefficient as a function of nozzle size for four operating pressures 10, 15, 20, e 30 psi (68,95, 103,42, 137,90 e 206,84 kPa) and for each manufacturer. It was used two precision pressure gauges (analogue and digital) calibrated agaisnt a dead weight gauge. Flow rates were obtained using three inductive electromagnetic gauges calibrated with volumetric readings. Nozzle diameters were measured using a profile projector model Starrett HB 400. The results evidence that the discharge coefficient varies with the diameter of the nozzle, the operation pressure and the convergence angle (constructive factor). The trials resulted Cds included in the range from 0.88 to 0.98, range for the analyzed issuers. The CUC was not different between the hydraulic systems with Cd designs considering medium and specific Cd for each nozzle.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2011-06-29
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.