Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.11.2008.tde-20062008-154913
Document
Auteur
Nom complet
Osvaldo Rettore Neto
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Piracicaba, 2008
Directeur
Jury
Miranda, Jarbas Honorio de (Président)
Botrel, Tarlei Arriel
Faria, Manoel Alves de
Titre en portugais
Metodologia para determinação da perda de carga localizada em emissores não coaxiais integrados a tubos de polietileno
Mots-clés en portugais
Irrigação localizada
Modelos matemáticos
Perda de carga.
Resumé en portugais
O procedimento de dimensionamento de uma linha lateral de irrigação localizada necessita ser avaliado com precisão, devido às perdas de carga tanto distribuídas na tubulação como nas inserções dos emissores com os tubos. Devido a isso, desenvolveu-se uma metodologia para a determinação da perda de carga localizada mediante a formulação de um modelo matemático a partir do índice de obstrução. Estas perdas localizadas podem ser significativas quando comparadas com as perdas de carga totais, devido ao grande número de emissores instalados ao longo da linha lateral. O experimento foi junto ao Departamento de Engenharia Rural (ESALQ-USP) e ajustado para valores número de Reynolds (R), no intervalo de 7.480 a 32.597 para proporcionar fluxo turbulento e velocidade máxima de 2,0 m s-1. A pesquisa foi conduzida em duas etapas: 1) ajuste do fator f para um seguimento de 0,5 m de tubo,sendo realizada 10 repetições, com o intuito de validação da metodologia empregada comparando-se o ajuste dos dados encontrados com os trabalhos existentes na literatura, 2) determinação da perda de carga (hf) em um seguimento de tubo de 1 m de comprimento com emissor devidamente vedado, portanto, pela diferença entre a hf do tubo mais o emissor e a hf do tubo obtido na primeira etapa, obteve-se a perda de carga localizada do emissor (hfe). Além disso, com a determinação da geometria do emissor, pelo projetor ótico HB 400, formulou-se uma equação que permitiu o cálculo da perda de carga localizada utilizando-se as características geométricas do emissor (comprimento do emissor, índice de obstrução e coeficiente de contração). Pelos resultados obtidos para 4 modelos utilizados, o modelo estimou satisfatoriamente para 2 modelos, e também verificou-se que o modelo apresentou um desempenho classificado como 'ótimo', portanto, podendo ser empregado para estimativa de perda de carga localizada provocada por emissores integrados não coaxiais com geometria semelhante ao emissor Uniram e Drip Net.
Titre en anglais
Methodology for Localized head loss determination of non coaxial emitters inserted in polyethylene pipe
Mots-clés en anglais
Contraction coefficient
Emitter
Head loss
Hydraulic radius.
Resumé en anglais
The design of a lateral line of trickle irrigation requires an accurate evaluation of head losses in not only the pipe but the emitters as well. A procedure was developed to determine localized head losses within the emitters by the formulation of a mathematical model accounting for the obstruction caused by the insertion point. These localized losses can be significant when compared with the total head losses within the system, due to the large number of emitters typically installed along the lateral line. An experiment was carried out by altering flow characteristics to create Reynolds Number (R) in the interval from 7480 to 32597 to provide turbulent flow and a maximum velocity of 2.0 m s-1. The geometry of the emitter point was determined by an optical projector and sensor. An equation was formulated that allows the localized head loss calculation using the geometric characteristics of the emitter (emitter length, obstruction index and the contraction coefficient). The obtained results for 4 used models, the model esteemed satisfactorily for 2 models, and was also verified that the model presents an acting classified as 'great', therefore, could be used to estimate localized head loss provoked by non coaxial emitters inserted in polyethylene pipe with similar geometry as the Uniram and Drip Net emitters.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
errataosvaldorettore.PDF (164.10 Kbytes)
osvaldorettore.pdf (1.08 Mbytes)