Master's Dissertation
DOI
https://doi.org/10.11606/D.11.2010.tde-19022010-093838
Document
Author
Full name
Carlos José Gonçalves de Souza Lima
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Piracicaba, 2009
Supervisor
Committee
Duarte, Sergio Nascimento (President)
Dias, Nildo da Silva
Miranda, Jarbas Honorio de
Title in Portuguese
Calibração e manejo de extratores providos de cápsulas porosas e transdutores de pressão para monitoramento de íons na fertirrigação
Keywords in Portuguese
Fertirrigação
Íons
Solos - Propriedades físico-químicas
Umidade do solo
Vácuo.
Abstract in Portuguese
O manejo da fertirrigação com controle da concentração de íons na solução do solo, apresenta-se como uma alternativa técnica e economicamente viável, sendo necessário a sua calibração para que possa ser efetivamente recomendada. Diante do exposto, este trabalho foi desenvolvido com o objetivo determinar equações de calibração a fim de serem utilizadas no monitoramento da condutividade elétrica (CE) e da concentração de íons na solução do solo em dois tipos de solo, com ênfase principal, diferentes intensidades de vácuo, tempo de aplicação do vácuo após o evento da fertirrigação e tempo após a aplicação do vácuo para realização de coleta da solução do solo. O estudo constou de dois experimentos realizados em condições de ambiente protegido. O delineamento estatístico utilizado foi o inteiramente casualizado (DIC) e tipos de solos foram os mesmos para ambos os experimentos, o primeiro em esquema fatorial 2 x 4 x 4, totalizando 32 tratamentos, com três repetições. Os tratamentos foram compostos por: dois tipos de solo (Franco Arenoso - S1 e Franco Argiloso - S2), quatro intensidades de vácuos aplicadas aos extratores (V1 - 50, V2 - 60, V3 - 70, e V4 - 80 kPa), e quatro níveis de umidade em base peso (100, 72, 61 e 43% no solo S1 e 100, 79, 66 e 60% no solo S2); e o segundo num esquema fatorial 2 x 4 x 3, totalizando 24 tratamentos, com três repetições. Os tratamentos constaram-se de quatro soluções com concentração de 0, 30, 60 e 90% da solução padrão utilizada e três intensidades de vácuos (V1 - 60, V2 - 70, V3 80 kPa). Os resultados obtidos demonstraram que é possível, com auxilio de extratores e transdutores de pressão, monitorar o volume e a concentração iônica da solução extraída com ótima precisão, bem como a variação de tensão em tempo real. O tempo mínimo para o equilíbrio iônico, foi de 30 horas após o evento de fertirrigação para aplicação do vácuo em ambos os solos. O tempo necessário entre a aplicação do vácuo até o momento da coleta da solução, aumentou em função da redução de umidade, bem como com o incremento do vácuo aplicado, a menor faixa de tempo observada foi de 0,37 a 0,67 horas na combinação da máxima umidade em ambos os solos com a maior e a menor intensidade de vácuo, respectivamente. A redução da umidade proporcionou um aumento na concentração iônica e na condutividade elétrica. O incremento do vácuo não afetou a concentração iônica para ambos os solos, exceto para K+, Ca2+, Mg2+ e SO4 2-, que tiveram suas concentrações reduzidas no solo (S1) e o volume coletado aumentou. Os níveis crescentes de concentração aplicada proporcionaram um aumento na concentração iônica e na (CE) da solução obtida, exceto o pH, que foi reduzido no solo (S2), já o incremento do vácuo aplicado não proporcionou efeito significativo para nenhum parâmetro avaliado em ambos os solos no Experimento II.
Title in English
Calibration and management of porous cap soil solution samplers and pressure transducers for monitoring fertigation ions
Keywords in English
Fertigation
Íon
Soil moisture
Soils Properties physic-chemical
Vacuum.
Abstract in English
The fertigation management with ion concentration control in the soil solution its an alternative technique and feasible economic, however its necessary to calibrate it to be effectively recommended. This work had the aim to determine calibrated equations to monitor the electrical conductivity (EC) and the solution ion concentration in soils of two different textures, with primary focus on different vacuum intensity, vacuum application time after the irrigation event and time after the vacuum application for collection of soil solution. The study consisted of two experiments under greenhouse condition. The statistic delineation utilized was the entirely randomized and the soil types were the same for both experiments; the first in the factorial scheme was 2 x 4 x 4, 32 treatments in the all, with three repetition. The treatments were composed of: two soil type ( loamsandy - S1 and loam-clayish- S2), four vacuum intensity applied to extractors (V1 - 50, V2 - 60, V3 - 70, and V4 - 80 kPa) and four levels of water content on weight base ( 100, 72, 61 e 43% in the soil S1 and 100, 79, 66 and 60% in the soil S2 ); the second in the factorial scheme was 2 x 4 x 3, 24 treatments in all, with three repetition. The treatments had four types of solution with concentration of the 0, 30, 60 e 90% in the utilized standard solution and three vacuum intensity (V1 - 60, V2 - 70, V3 80 kPa). The results showed that its possible, to monitor the volume and ionic concentration of extracted solution with high precision and also the tension variation in real time with the help of extractors and pressure to transductors. The minimum time for ionic equilibrium was the 30 hours after the fertigation event to apply the vacuum in both soils. The necessary time between vacuum applications until the moment of collection of solution, increased with the reduction of water content in soil, and also due to increment in the applied vacuum. The smaller time range observed was from the 0.37 to 0.67 hours under the combination of the maximum water content in both soils with the bigger and smaller vacuum intensity, respectively. The water content reduction resulted an increase in the ionic concentration and electrical conductivity. The vacuum increment did not affect ionic concentration in both soils, except for K+, Ca2+, Mg2+ and SO4 2-, which were reduced in the soil S1 and the collected volume increased. The increasing level of the applied concentration provided an increase in the ionic concentration and in the EC of the obtained solution, except for pH, that which reduced in the soil S2; the applied vacuum increment did not affect significantly evaluated parameters in both soils in the second experiment.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Carlos_Lima.pdf (5.06 Mbytes)
Publishing Date
2010-03-08
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.