• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.11.2009.tde-10092009-081324
Document
Auteur
Nom complet
Mariana Ventura Martins
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Piracicaba, 2009
Directeur
Jury
Libardi, Paulo Leonel (Président)
Alves, Marlene Cristina
Silva, Alvaro Pires da
Titre en portugais
Influência da distância de instalação de tensiômetros no campo para o cálculo do gradiente de potencial total no método do perfil instantâneo
Mots-clés en portugais
Água do solo
Condutividade hidráulica do solo - Determinação - Métodos.
Resumé en portugais
Para determinar a condutividade hidráulica do solo em condições de não saturação, o método mais utilizado para estimativas no campo tem sido o do perfil instantâneo. Este método baseia-se na integração da equação de Richards em relação à profundidade do solo, durante o processo de redistribuição da água, após a saturação do perfil até a profundidade de interesse e prevenção do fluxo de água pela superfície do solo. A equação resultante para a aplicação do método exige o conhecimento do gradiente de potencial total na profundidade de interesse, durante o processo de redistribuição. A hipótese básica do trabalho é a de que há uma distância correta entre as cápsulas do tensiômetro, para o cálculo do gradiente de potencial total, na aplicação do método do perfil instantâneo, que confere menor erro à determinação da condutividade hidráulica. Em dois solos com texturas bem diferentes foi instalada uma estrutura metálica retangular de 4,50 m de comprimento, 3,00 m de largura e 0,60 m de altura (0,40 m no solo), no centro da qual foram instalados 26 tensiômetros com manômetro de mercúrio a cada 25 mm, desde 0,10 até 0,60 m de profundidade, para o cálculo do gradiente de potencial total na profundidade de 0,50 m. O gradiente de potencial total utilizado como referência foi calculado pela derivada de equação de ajuste do potencial total com a profundidade do solo; os demais gradientes foram calculados pelo método das diferenças finitas utilizando, para o comprimento do solo (distância entre as cápsulas), os valores 0,05, 0,10, 0,15 e 0,20 m. Destes valores somente a distância 0,05 m resultou em gradientes diferentes em relação à referência para os dois solos testados, com o que pode-se recomendar os demais comprimentos para o cálculo do gradiente de potencial total no método do perfil instantâneo. Também pode-se concluir que para o solo arenoso a hipótese do gradiente unitário não se adequou corretamente aos dados, subestimando em até 75% o valor da condutividade hidráulica.
Titre en anglais
Influence of the distance of installation of tensiometers to calculate total potential gradient in the field soil hydraulic conductivity determination
Mots-clés en anglais
Soil hydraulic conductivity-Determination-Methods.
Soil water
Resumé en anglais
The soil hydraulic conductivity determination method most used under unsaturated field conditions is the instantaneous profile method. This method is based on the integration of Richards equation in relation to soil depth, during the soil water redistribution process, after the profile has been saturated till the interest depth and the soil surface prevented to water flux. The equation that results from the method requires the knowledge of the total potential gradient at the interest depth during the redistribution depth. The basic hypothesis of this work is that there is an installation correct distance of the tensiometer porous cups to calculate the total potential gradient in the instantaneous profile method that provides less error to the hydraulic conductivity determination. In two very distinct texture soil. A metallical rectangular structure of 4.50 m length, 3.00 m width and 0.60 m depth was installed into the soil profile, leaving 0.20 m of its depth above the soil surface. In the center of the delimited area, 26 mercury tensiometers were installed at each 25 mm along the profile from soil depth of 0.10 m to 0.60 m, to calculate the total potential gradient at the 0.50 m soil depth. The gradient used as reference was that calculated by differentiation of the fitted curve of total potential as a function of the vertical position coordinate for the depth of 0.50 m; the other gradients were calculated by finite differences using the distances of 0.05, 0.10, 0.15 and 0.20 m between installed porous cups. Among these values, only the distance of 0.05 m resulted in gradients different of the reference for both soils. Therefore, the other distances (0.10, 0.15 and 0.20 m) away be recommended to calculated the soil water total potential by finite differences in the instantaneous profile method. Would be concluded that the assumption of unit gradient was not suitable for the data obtained for the sandy soil, underestimating the hydraulic conductivity by up to 75%.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Mariana_Martins.pdf (1.58 Mbytes)
Date de Publication
2009-09-17
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.