• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.11.2017.tde-23012017-173410
Document
Auteur
Nom complet
Tatiane Barbosa Coitinho
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Piracicaba, 2016
Directeur
Jury
Machado, Paulo Fernando (Président)
Cassoli, Laerte Dagher
Domingues, Maria Antonia Calori
Nespolo, Cassia Regina
Santos, Marcos Veiga dos
Titre en portugais
Aplicação da espectroscopia de infravermelho com transformada de Fourier no monitoramento de adulterantes em leite cru
Mots-clés en portugais
Adulteração
Calibração
Fraude
FTIR
Laticínios
Validação
Resumé en portugais
A adulteração do leite é uma prática comum e que preocupa as agências reguladoras, indústrias e a população. Apesar da crescente necessidade de identificação desse tipo de fraude, os métodos empregados geralmente possuem baixo rendimento analítico e alta dependência de mão-de-obra. Sendo assim, objetivou-se desenvolver calibração e validação para monitoramento de adulteração em leite cru, utilizando equipamento compacto (MilkoScan FT1), que adota a espectroscopia de infravermelho com transformada de Fourier (FTIR). Ademais, objetivou-se comparar a acurácia na detecção de adulterantes do método de FTIR com os testes físico-químicos tradicionais adotados pela indústria no controle de qualidade do leite. Para isso, cerca de 2500 amostras de leite foram utilizadas para construção do espectro de referência e 1625 amostras foram empregadas para validar a identificação de cinco dos principais adulterantes (em três diferentes concentrações cada) encontrados em leite: (1) amido de milho; (2) bicarbonato de sódio; (3) citrato de sódio; (4) formaldeído; (5) sacarose, além da adição de dois níveis de água ou soro de leite. Após esta etapa, 650 amostras foram preparadas para comparação dos métodos, utilizando os mesmos adulterantes nas mesmas concentrações da etapa anterior. Os resultados demonstraram que as calibrações desenvolvidas expressaram boa capacidade geral de detecção de adulteração, apresentando excelente sensibilidade (84%) e especificidade (100%), principalmente quando comparadas com os testes tradicionais, visto que o método de FTIR apresentou capacidade de identificação de adulterantes em leite cru superior aos métodos físico-químicos tradicionais, podendo ser utilizado diretamente nas plataformas de recepção do leite nos laticínios, melhorando os processos industriais de detecção de adulterantes.
Titre en anglais
Application of Fourier transform infrared spectroscopy to monitoring adulterants in raw milk
Mots-clés en anglais
Adulteration
Calibration
Dairy industry
Fraud
FTIR
Validation
Resumé en anglais
Milk adulteration is a common practice that concerns regulatory agencies, industry and the population. Despite the growing need for the identification of this type of fraud, the methods employed generally present low performance and high dependency on hand labor. Therefore, this study aimed to calibrate and validate a compact equipment (MilkoScan FT1) that adopts a Fourier transform infrared spectroscopy to monitor adulteration in raw milk. Furthermore, this study aimed to compare the accuracy in adulterants detection, of the FTIR method with that of conventional physico-chemical tests, adopted by the dairy industry in milk quality control. For this, almost 2500 milk samples were used for reference spectrum construction and 1625 samples were used in the validation process, to identification of the following five main adulterants (at three different concentrations) found in milk: (1) cornstarch, (2) sodium bicarbonate, (3) sodium citrate, (4) formaldehyde, and (5) saccharose, plus the additions of two levels of water or whey. After this step, 650 samples were prepared to compare the methods, using the same adulterants at the same concentrations of the previous step. The results revealed that the developed calibration demonstrated a good adulteration detection ability with excellent sensitivity (84%) and specificity (100%), mainly when compared with traditional tests. The FTIR method showed capacity of adulterants identification higher than that presented by physico-chemical methods, which proves its ability to be used directly in the milk reception platforms in dairy industry, improving industrial processes of adulterants detection.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2017-02-02
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.