• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.11.2017.tde-23012017-173410
Documento
Autor
Nombre completo
Tatiane Barbosa Coitinho
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Piracicaba, 2016
Director
Tribunal
Machado, Paulo Fernando (Presidente)
Cassoli, Laerte Dagher
Domingues, Maria Antonia Calori
Nespolo, Cassia Regina
Santos, Marcos Veiga dos
Título en portugués
Aplicação da espectroscopia de infravermelho com transformada de Fourier no monitoramento de adulterantes em leite cru
Palabras clave en portugués
Adulteração
Calibração
Fraude
FTIR
Laticínios
Validação
Resumen en portugués
A adulteração do leite é uma prática comum e que preocupa as agências reguladoras, indústrias e a população. Apesar da crescente necessidade de identificação desse tipo de fraude, os métodos empregados geralmente possuem baixo rendimento analítico e alta dependência de mão-de-obra. Sendo assim, objetivou-se desenvolver calibração e validação para monitoramento de adulteração em leite cru, utilizando equipamento compacto (MilkoScan FT1), que adota a espectroscopia de infravermelho com transformada de Fourier (FTIR). Ademais, objetivou-se comparar a acurácia na detecção de adulterantes do método de FTIR com os testes físico-químicos tradicionais adotados pela indústria no controle de qualidade do leite. Para isso, cerca de 2500 amostras de leite foram utilizadas para construção do espectro de referência e 1625 amostras foram empregadas para validar a identificação de cinco dos principais adulterantes (em três diferentes concentrações cada) encontrados em leite: (1) amido de milho; (2) bicarbonato de sódio; (3) citrato de sódio; (4) formaldeído; (5) sacarose, além da adição de dois níveis de água ou soro de leite. Após esta etapa, 650 amostras foram preparadas para comparação dos métodos, utilizando os mesmos adulterantes nas mesmas concentrações da etapa anterior. Os resultados demonstraram que as calibrações desenvolvidas expressaram boa capacidade geral de detecção de adulteração, apresentando excelente sensibilidade (84%) e especificidade (100%), principalmente quando comparadas com os testes tradicionais, visto que o método de FTIR apresentou capacidade de identificação de adulterantes em leite cru superior aos métodos físico-químicos tradicionais, podendo ser utilizado diretamente nas plataformas de recepção do leite nos laticínios, melhorando os processos industriais de detecção de adulterantes.
Título en inglés
Application of Fourier transform infrared spectroscopy to monitoring adulterants in raw milk
Palabras clave en inglés
Adulteration
Calibration
Dairy industry
Fraud
FTIR
Validation
Resumen en inglés
Milk adulteration is a common practice that concerns regulatory agencies, industry and the population. Despite the growing need for the identification of this type of fraud, the methods employed generally present low performance and high dependency on hand labor. Therefore, this study aimed to calibrate and validate a compact equipment (MilkoScan FT1) that adopts a Fourier transform infrared spectroscopy to monitor adulteration in raw milk. Furthermore, this study aimed to compare the accuracy in adulterants detection, of the FTIR method with that of conventional physico-chemical tests, adopted by the dairy industry in milk quality control. For this, almost 2500 milk samples were used for reference spectrum construction and 1625 samples were used in the validation process, to identification of the following five main adulterants (at three different concentrations) found in milk: (1) cornstarch, (2) sodium bicarbonate, (3) sodium citrate, (4) formaldehyde, and (5) saccharose, plus the additions of two levels of water or whey. After this step, 650 samples were prepared to compare the methods, using the same adulterants at the same concentrations of the previous step. The results revealed that the developed calibration demonstrated a good adulteration detection ability with excellent sensitivity (84%) and specificity (100%), mainly when compared with traditional tests. The FTIR method showed capacity of adulterants identification higher than that presented by physico-chemical methods, which proves its ability to be used directly in the milk reception platforms in dairy industry, improving industrial processes of adulterants detection.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2017-02-02
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.