Thèse de Doctorat
DOI
https://doi.org/10.11606/T.106.2014.tde-16122014-000110
Document
Auteur
Nom complet
Ricardo da Silva Benedito
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2014
Directeur
Jury
Zilles, Roberto (Président)
Macêdo, Wilson Negrão
Pigueiras, Eduardo Lorenzo
Pinho, João Tavares
Sueta, Helio Eiji
Titre en portugais
Análise de um mecanismo de compensação de reativos incorporado aos inversores de um sistema fotovoltaico conectado à rede elétrica
Mots-clés en portugais
compensação de reativos
geração distribuída
sistemas fotovoltaicos conectados à rede
Resumé en portugais
No Brasil, quando uma unidade consumidora (UC) sob regime de microgeração ou de minigeração distribuída tem parte ou a totalidade da sua demanda por potência ativa suprida pela planta geradora, mas sua demanda por potência reativa é atendida exclusivamente pela rede elétrica, verifica-se uma aparente deterioração do fator de potência dessa UC, sob a ótica da concessionária. Esse efeito decorre do fato de que o fator de potência, de acordo com a regulamentação vigente, é determinado apenas a partir das medições dos fluxos de potência ativa e reativa trocados entre a UC e a rede elétrica e não também entre a planta geradora e UC. Para consumidores do Grupo A (tensão de fornecimento igual ou superior a 2,3 kV) nessa situação, de acordo com o perfil da carga, pode haver cobrança por excedentes de reativos, constituindo-se assim uma barreira. Especificamente no caso de sistemas fotovoltaicos conectados à rede, existe a possibilidade de se utilizar os próprios inversores c.c.-c.a para suprir a demanda de reativos da UC e, dessa forma, minimizar o problema apresentado. Com o objetivo de se avaliar essa alternativa no contexto brasileiro, tendo-se em vista condições reais de operação e os limites normativos de injeção de potência reativa para inversores de sistemas fotovoltaicos, foi realizado um estudo de caso de uma planta fotovoltaica instalada no telhado do prédio da Administração do Instituto de Energia e Ambiente da Universidade de São Paulo. O estudo mostrou que a compensação realizada por meio do inversor selecionado evitou a cobrança de excedentes de reativos sem afetar de forma significativa a produtividade do sistema fotovoltaico. Do ponto de vista elétrico, verificou-se que a injeção de reativos pelo inversor não provocou variações significativas de tensão no ponto de acoplamento ou no alimentador e, ainda, se verificou considerável liberação de capacidade do sistema supridor da concessionária. Dessa forma, a análise dos resultados indica uma tendência a se considerar a compensação de reativos proporcionada pelo próprio inversor a opção mais viável para se lidar com os excedentes de reativos, comparativamente a métodos convencionais de compensação ou à situação em que nenhuma ação compensatória seja implementada.
Titre en anglais
Analysis of a reactive power compensation mechanism incorporated into inverters of a grid-connected photovoltaic system
Mots-clés en anglais
distributed generation
grid-connected photovoltaic systems
reactive power compensation
Resumé en anglais
In Brazil, when a consumer unit (CU) under a distributed microgeneration or minigeneration scheme has part or all of its demand for active power supplied by the generating plant, but its demand for reactive power is served exclusively by the grid, the power factor of this CU appears deteriorated, from the perspective of the utility. This effect is due to the fact the power factor, according to the current regulations, is determined only from measurements of the flows of active and reactive power exchanged between the UC and the grid and not also between the generating plant and UC. Users of group A (supply voltage equal to or greater than 2.3 kV) in this situation, according to the CU load profile, may be charged due the reactive power excess, thus constituting a barrier. Specifically in the case of grid-connected photovoltaic systems, there is the possibility of using the d.c.- a.c. inverters to suply the CU reactive power demand and, thus, minimizing the presented problem. In order to evaluate this alternative in the Brazilian context, keeping in view real operating conditions and regulatory limits for the reactive power injection for photovoltaic inverters, we conducted a case study with a photovoltaic plant installed on the roof of the University of São Paulo Institute for Energy and Environment administration building. The study showed that the compensation performed by the selected inverter prevented the reactive power excess charging without affecting significantly the photovoltaic system productivity. From an electrical point of view, it was found that the injection of reactive power by the inverter did not cause significant voltage variations at the coupling point or at the transformer and, additionally, there was a significant release in the utility suply system capacity. Thus, the analysis results indicates a tendency to consider the compensation provided by the inverter itself the most viable option for dealing with the surplus of reactive power compared to conventional compensation methods or to the situation in which no compensatory action is implemented.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2015-01-27
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.