• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.10.2017.tde-27072017-155416
Documento
Autor
Nombre completo
Thales Bregadioli
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2017
Director
Tribunal
Ferrigno, Cassio Ricardo Auada (Presidente)
Belangero, William Dias
Souza, Alexandre Navarro Alves de
Título en portugués
Comparação biomecânica e da redução óssea do Clamp and Rod Internal Fixation e placa de reconstrução bloqueada em fraturas de acetábulo
Palabras clave en portugués
Bioengenharia
Cães
Cartilagem articular
Consolidação da Fratura
Fixação interna de fraturas
Resumen en portugués
Este estudo objetivou comparar, biomecanicamente, por meio dos ensaios de flexão destrutível e ciclagem, bem como a qualidade da redução óssea, após avaliação do molde da superfície articular de osteotomias centrais do acetábulo de cão fixadas com Clamp and Rod Internal Fixation (CRIF) 2,7 mm ou placa de reconstrução bloqueada 2,7 mm. Os implantes foram divididos em dois grupos, denominados grupo CRIF (GC) e grupo Placa (GP). Foram utilizadas nove pelves de cadáveres de cão com peso corporal entre 15 e 35 kg, posteriormente as pelves foram subdivididas em 18 hemipelves e distribuídas aleatoriamente para testar os dois implantes, um contralateral ao outro em uma mesma pelve. Para realização dos testes, foi simulado uma fratura central no acetábulo, por meio de osteotomia linear, realizada com auxílio de serra oscilatória e em seguida, fixadas segundo os padrões AO/SIF, sendo utilizados três parafusos craniais e dois caudais a osteotomia. Após comparação biomecânica de resistência máxima à flexão o GP (22,38±8,44 N.m) demonstrou superioridade estatística em relação ao GC (15,60±5,76 N.m), (p=0,02408). Na comparação do molde da superfície articular após 30 ciclos o GP (0,27 ± 0,24mm) demonstrou valores menores para lacuna da linha articular que o GC (0,49 ± 0,29mm), sendo o GP estatisticamente superior, (p=0,04784). Em conclusão, a aplicação da placa de reconstrução bloqueada é simples e deve ser considerada para redução de fraturas do acetábulo que necessitem de reconstrução anatômica.
Título en inglés
Comparação biomecânica e da redução óssea de Clamp and Rod Internal Fixation (CRIF) e placa de reconstrução bloqueada em fraturas de acetábulo
Palabras clave en inglés
Bioengineering
Cartilage Articular
Dogs
Fracture Fixation Internal
Fracture Healing
Resumen en inglés
The aim of this study was to compare the accuracy of reduction and biomechanical characteristics of acetabular osteotomies repaired with 2.7-mm Clamp and Rod Internal Fixation (CRIF) constructs or 2.7-mm locking reconstruction plates in cyclic and load to failure flexion tests. Nine dog cadavers with body weight between 15 and 35 kg were included in this study. All 18 hemipelves were randomly assigned into two groups named after the implants tested, group CRIF (GC) and group Plate (GP). All pelves were used to test both groups with each hemipelvis belonging to a different implant group. Acetabular osteotomies were created with an oscillatory saw and then fixed according to the AO/ASIF standards, using either 5-hole, 2.7-mm locking reconstruction plates with three locked screws cranial and two caudal to the osteotomy line, or CRIF constructs with 5 clamps, three located cranial and two caudal to the osteotomy line. Load to failure at GP (22.38 ± 8.44N.m) was significantly higher than GC (15.60 ± 5.76N.m), (p = 0.02408). Imprinted cast of acetabular reduction gap after 30 cycles was statistically smaller at GP (0.27 ± 0.24mm) than GC (0.49 ± 0.29mm) (p = 0.04784). We concluded that the appliance of locking reconstruction plates is simple and should be considered for acetabular fractures, that require perfect anatomical reconstruction.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2017-08-22
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.