• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.10.2012.tde-25092013-151150
Document
Author
Full name
Carina Outi Baroni
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2012
Supervisor
Committee
Pinto, Ana Carolina Brandão de Campos Fonseca (President)
Amaku, Marcos
Muramoto, Caterina
Title in Portuguese
Efetividade dos filtros empregados em imagens radiográficas digitais na detecção dos quadros pulmonares de cães e gatos
Keywords in Portuguese
Filtro convencional
Filtro invertido
Filtro realce de borda
Pulmões
Radiografia computadorizada
Abstract in Portuguese
A transição do sistema radiográfico convencional para os sistemas radiográficos digitais, ao longo de vinte anos, tem transformado as salas de laudos nos Serviços de Diagnóstico por Imagem tanto na Medicina quanto na Medicina Veterinária. Atualmente, com a introdução do sistema radiográfico computadorizado na rotina de alguns hospitais e laboratório de imagem, o uso das ferramentas do pós-processamento tem se tornado mais freqüente. Diante das vantagens e desvantagens destas ferramentas e da escassez de trabalhos a cerca dos filtros utilizados em imagens radiográficas digitais, o objetivo deste trabalho foi testar o uso dos filtros convencional, realce de borda e invertido, assim como a associação deles na detecção dos padrões pulmonares de cães e gatos. Foram selecionados 40 exames radiográficos do tórax de cães e gatos contendo as três projeções de eleição. Três observadores com diferentes graus de experiência e familiaridade com o sistema radiográfico computadorizado analisaram os filtros individualmente e depois em associação na detecção geral dos padrões pulmanres e individualmente. Obteve-se melhores valores de sensibilidade e especificidade, em geral, quando os observadores experientes utilizaram os três filtros em associação e, para o iniciante, os melhores resultados da sensibilidade e especificidade, em geral, foram no filtro convencional. Os resultados deste trabalho permitiram concluir que houve diferença estatística entre os observadores com distintos graus de experiência e familiaridade com o sistema digital. E que o uso em associação dos filtros pode incrementar o desempenho do radiologista na avaliação radiográfica do parênquima pulmonar.
Title in English
Effectivity of the filters used in radiographic digital imaging in the detection of pulmonary patterns in dogs and cats
Keywords in English
Computed radiography
Edge enhancement filter
Gray scale reversed filter
Lungs
Standard filter
Abstract in English
The transition of the conventional radiographic system to the digital one has been transforming the radiographic routine human and veterinary medicine over the last twenty years. Currently, the introduction of the computed radiography system in some hospitals and imaging services has increased the use of post processing tools. Considering the advantages and disadvantages of these tools and the lack of knowledge about the filters used in digital radiographic images, the aim of this study was to test efficacy of the standard, edge enhancement and gray scale reversed filters and their association to detect pulmonary patterns of cats and dogs. This work selected forty canine and feline sets of thoracic radiographs, including three projections. Three different observers with different degrees of experience and familiarity with the computed radiographic system analyzed the filters individually and then associated in order to detect pulmonary patterns. The best results in sensibility and specificity were related to the more experienced observers using the three associated filters. However, for the beginner, the best sensibility and specificity results was reached with the use of the standard filter in general results. In conclusion were statistical differences between more experienced and familiarized observers with the digital system and the use of filters can increase the radiologist performance when evaluating the pulmonary patterns on the radiography.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2013-10-16
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.