• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.10.2008.tde-22042009-100210
Documento
Autor
Nombre completo
Rodrigo Crispim Moreira
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2008
Director
Tribunal
Zoppa, André Luis do Valle de (Presidente)
Rasera, Luciane
Silva, Luis Claudio Lopes Correia da
Título en portugués
Estudo biomecânico do terceiro metacarpiano de eqüinos
Palabras clave en portugués
Ensaios biomecânico
Eqüino
Osso
Resumen en portugués
Testes biomecânicos de ossos são utilizados para determinar as propriedades mecânicas dos mesmos, e são um importante adjunto para pesquisadores desenvolverem implantes metálicos e protocolos de fixação de fraturas. O Objetivo desse foi determinar as propriedades biomecânicas do tecido ósseo de diferentes regiões do terceiro metacarpiano eqüino submetido a ensaios de compressão e flexão. Foram utilizados 30 pares de terceiro metacarpiano eqüino divididos em dois grupos com um membro de cada par. No teste de flexão em três pontos, o osso inteiro apoiado em dois suportes cilíndricos de 20 mm de diâmetro e 150 mm distantes entre si, recebeu uma carga através de um cutelo com mesmo diâmetro dos suportes e posicionado a 75 mm entre os apoios, na direção palmaro-dorsal até que ocorresse a fratura. No teste de compressão foram utilizadas amostras de diferentes regiões do osso. O corpo de prova 1 (cp1) foi composto pela diáfise média e seu comprimento foi igual a duas vezes ao diâmetro latero-medial no ponto médio do osso que coincidia com o ponto médio do corpo de prova. O grupo cp1 foi submetido a carga compressiva no sentido próximo-distal até a carga máxima de 4000 kgf. Com auxílio de trefina foram feitos corpos de prova, no sentido longitudinal, dos fragmentos de ossos restantes do corte acima descrito. Dois desses corpos de prova foram coletados do centro da porção trabecular das epífises proximal (cp2) e distal (cp3). Outros dois corpos de prova foram coletados da região cortical lateral (cp4L) e medial (cp4M) da diáfise. Esses corpos de prova foram submetidos a carga compressiva no sentido próximo-distal até fraturarem. Os resultados obtidos nos permitem concluir que na diáfise, o córtex medial resiste a uma tensão maior e apresenta um módulo de elasticidade maior que o córtex lateral; o osso trabecular na epífise distal apresenta mesmo módulo de elasticidade que na epífise próximal, contudo suporta uma tensão maior no momento da fratura.
Título en inglés
Biomechanical study of the equine third metacarpal bone
Palabras clave en inglés
Biomechanical test
Bone
Equine
Resumen en inglés
Bone properties determined by biomechanical testing are extremely important for both metallic implants and osteosyntesis protocols development. The objective of this study was determining the biomechanical properties of some different regions of third metacarpal bone submitted to compression and bending tensions, using thirty pairs divided into two groups, each group formed by one limb of each pair. During the three points bending test the dorsal surface of the entire bone was placed upon two cylindrical bases 150 mm far from each one, and load was applied in the mid point on the palmar aspect of the bone, 75 mm far from each cylindrical base, until bones failure. For the compression test samples of different bone regions were used. The mid diaphysis was used as samples (cp1), which its height was twice its latero-lateral thickness at the mid point of the bone length. All cp1 were submitted to proximo-distal compressive loads until it reached 4000kgf. Using a trefina the others samples were obtained from the fragments of bone not used for the cp1 confection. Two of them were collected from the trabecular portion of proximal (cp2) and distal (cp3) epiphysis, and the others from lateral (cp4L) and medial (cp4m) cortex region of diaphysis. All of them were submitted to proximo-distal compressive load until their failure. By the analysis of the results obtained was concluded that the medial cortex is more resistant to tensions and has greater elastic modulus than the medial cortex, at the diaphyseal region; the trabecular bone at the distal epiphysis has the same elastic modulus than at the proximal epiphysis, however its failures occurs at greater loads.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2009-06-25
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.