• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.10.2016.tde-12082015-173730
Document
Author
Full name
Ísis dos Santos Dal Bó
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2015
Supervisor
Committee
Ferrigno, Cassio Ricardo Auada (President)
Garcia Filho, Reynaldo Jesus
Zoppa, André Luis do Valle de
Title in Portuguese
Estudo biomecânico comparativo da resistência de segmentos ósseos de rádios de cães autoclavados ou desvitalizados em nitrogênio líquido
Keywords in Portuguese
Cirurgia de preservação do membro
Ensaio de flexão em quarto pontos
Ortopedia
Osteossarcoma
Abstract in Portuguese
O presente estudo visa comparar biomecanicamente, por meio do ensaio de flexão em quatro pontos, a resistência de segmentos de rádios de cães autoclavados e desvitalizados em nitrogênio líquido. Foram utilizados 20 cadáveres de cães de mais de dois anos de idade e massa corporal superior a 20 kg, portanto 40 rádios, que foram divididos em quatro grupos: grupo autoclave (GA), grupo controle autoclave (GCA), grupo nitrogênio (GN) e grupo controle nitrogênio (GCN). Os corpos de prova dos grupos GCA e GCN pertenciam ao lado contralateral dos grupos GA e GN, respectivamente. Os ossos foram autoclavados a 121ºC, por 20 min a 2 atm. A desvitalização em nitrogênio foi realizada por meio da imersão em nitrogênio líquido, por 20 min, seguida de descongelamento à temperatura ambiente, sendo finalizada por imersão em solução de NaCL a 0,9%, por mais 15 min. A avaliação da resistência biomecânica foi realizada pelo ensaio de flexão em quatro pontos. Foi utilizado o programa de computador PMI para calcular o momento de inércia após o ensaio biomecânico destrutivo. Foram comparadas as variáveis força máxima, rigidez, altura máxima à secção transversa do corpo de prova, deslocamento do baricentro em relação ao eixo x, flecha, tensão-tração, tensão compressão e tensão máxima. Não foram encontradas diferenças estatisticamente significantes entre os grupos GN e GCN. Foram encontradas diferenças estatisticamente significantes entre os grupos GA e GCA somente na comparação da variável força máxima. A análise das variáveis tensão-tração, tensão-compressão e tensão máxima evidenciou diferenças estatisticamente significantes entre os grupos GA e GN, sendo os valores maiores para o grupo GA. Também foi realizada comparação entre os deltas (GN menos GCN e GA menos GCA) em que não foram observadas diferenças estatísticas.
Title in English
Biomechanical comparative study of the strength of autoclaved and devitalized in liquid nitrogen bone segments from the radius of dogs
Keywords in English
Four points bending test
Limb-sparing surgery
Orthopaedic
Osteosarcoma
Abstract in English
The present study aim to, biomechanically compare through the four points bending test, the strenght of autoclaved and devitalized in liquid nitrogen radius segments. 20 corpses of dogs (>2 years of age and >20 kg of weight) were used. 40 radius were collected and divided into 4 groups, Autoclave Group (GA), Control Autoclave Group (GCA), Nitrogen Group (NG) and Control Nitrogen Group (GCN). Bone segments from groups GCA and GCN were contralateral to GA and NG. The segments were autoclaved at 121ºC and 2 atm for 20 minutes. Nitrogen devitalization of the bone segments was obtained by 20 minutes immersion, followed by thawing at room temperature and 15 minutes immersion in 0,9% NaCL solution. The biomechanical strenght evaluation was performed in the four points bending test; afterwards, PMI computer program calculated the moment of inertia after the destructive biomechanical assay. Variables compared were maximum strength, stiffness, maximum high trough the transverse section of the bone segment, centers of mass dislocation in relation to x axe, arrow, stress-tension, stress-compression and maximum stress. No statistically significant differences between the GN and GCN groups were found. Statistically significant differences were found between groups GA and GCA only in the comparison of the maximum force variable. The analysis of variable stress-tension, stress-compression and maximum stress showed statistically significant differences between the GA and GN groups, with higher values for the GA group. Comparison of the deltas (GN least GCN and GA least GCA) that no statistical differences were observed was also performed.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2016-03-23
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.