• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.10.2006.tde-23082007-132820
Document
Auteur
Nom complet
Lilian Caram Petrus
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2006
Directeur
Jury
Larsson, Maria Helena Matiko Akao (Président)
Fernandes, Wilson Roberto
Schwartz, Denise Saretta
Titre en portugais
Avaliação dos fluxos das valvas aórtica e pulmonar com ecocardiografia Doppler pulsátil em cães clinicamente sadios
Mots-clés en portugais
Cães sadios
Doppler pulsátil
Ecocardiografia Doppler
Resumé en portugais
O objetivo do presente estudo foi avaliar os fluxos das valvas aórtica (AO) e pulmonar (Pul) por meio de análise qualitativa (presença de regurgitações valvares e características do espectro avaliado) e quantitativa, com obtenção de parâmetros ecocardiográficos como velocidades máxima (V. Max.) e média (V. Me.), integral de velocidade (VTI), tempo de aceleração (TA) e ejeção (TE), volume sistólico (VS) e débito cardíaco (DC). Foram utilizados 30 cães, que após considerados clinicamente sadios por meio de exames físico, laboratoriais, eletrocardiográfico, ecocardiográfico (modos uni e bidimensional), radiográfico de tórax e mensuração da pressão arterial sistêmica, obtiveram-se os seguintes resultados para os referidos parâmetros: V.max. AO= 1,215 + 19,38 m/s; V. Me. AO= 0,722 + 0,08206 m/s; VTI AO= 0,141 + 0,02426m; TA AO= 38,80 + 11,29 ms; TE AO= 197,9 + 24,77 ms; VS AO= 29,63 + 14,59 mL; DC AO= 2,940 + 1,260 L/ min.; V. Max. Pul= 0,9457 + 0,1792 m/s; V. Me. Pul= 0,632 + 0,09960 m/s; VTI Pul= 0,1267 + 0,02324 m; TA Pul= 70,97 + 18,87 ms; TE Pul= 203,7 + 28,98 ms; VS Pul= 28,52 + 17,96 mL; DC Pul= 3,056 + 1,546 L/ min.. Em apenas três animais observou-se regurgitação pulmonar. Alguns parâmetros tiveram correlação negativa com a variável freqüência cardíaca (VTI AO, TE AO, VTI Pul, TA Pul, TE Pul, VS Pul), outros correlação positiva com a variável peso (VTI AO, TA AO, TE AO, VS AO, DC AO, VTI Pul, TE Pul, VS Pul, DC Pul), não sendo encontrada influência da variável sexo na maioria dos parâmetros avaliados. Na comparação entre os dois fluxos, observaram-se V. Max. AO e V. Me. AO maiores que V. Max. Pul. e V. Me. Pul., respectivamente, VTI AO maior que VTI Pul, e TA AO menor que TA Pul. Observada ainda uma correlação positiva e significativa entre VS AO e VS Pul e entre DC AO e DC Pul.
Titre en anglais
Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in clinically normal dogs
Mots-clés en anglais
Doppler Echocardiography
Healthy dogs
Pulsed-wave Doppler
Resumé en anglais
The purpose of this study was the evaluation of aortic (AO) and pulmonary (Pul) valves flow for the qualitative (valvar insufficiency presence, characteristic of flow profile) and quantitative analysis, obtaining this way chocardiographic parameters as: peak (PV) and mean (MV) velocities, velocity-time integral (VTI), acceleration (AT) and ejection (ET) time, stroke volume (SV) and cardiac output (CO). Thirty dogs were studied, and to be considered normal, physical, laboratory, electrocardiographic, echocardiographic (uni and bidimensional mode) exams, torax radiographs, and measurement of the blood pressure were accomplished, and the following echocardiographic parameters were obtained: AO PV= 1,215 19,38 m/s; AO MV= 0,722 + 0,08206 m/s; AO VTI= 0,141 + 0,02426m; AO AT= 38,80 + 11,29 ms; AO ET= 197,9 + 24,77 ms; AO SV= 29,63 + 14,59 mL; AO CO= 2,940 + 1,260 L/ min.; Pul PV= 0,9457 + 0,1792 m/s; Pul MV= 0,632 + 0,09960 m/s; Pul VTI= 0,1267 + 0,02324 m; Pul AT= 70,97 + 18,87 ms; Pul ET= 203,7 + 28,98 ms; Pul SV= 28,52 + 17,96 mL; Pul CO= 3,056 + 1,546 L/ min. The variable heart rate had negative correlation with AO VTI, AO ET, Pul VTI, Pul AT, Pul ET, Pul SV, and the variable weight had positive correlation with AO VTI, AO AT, AO ET, AO SV, AO CO, Pul VTI, Pul ET, Pul SV, Pul CO, differently from the variable sex, that had no influence on the evaluated parameters. The comparation of aortic and pulmonary valves flow demonstrated AO PV and AO MV higher than Pul PV and Pul MV, respectively, AO VTI higher than Pul VTI, and Pul AT higher than AO AT. The statistical evaluation also showed a strong and positive correlation between AO SV and Pul SV and between AO CO and Pul CO.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2007-09-11
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.