• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.10.2006.tde-23082007-132820
Documento
Autor
Nombre completo
Lilian Caram Petrus
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2006
Director
Tribunal
Larsson, Maria Helena Matiko Akao (Presidente)
Fernandes, Wilson Roberto
Schwartz, Denise Saretta
Título en portugués
Avaliação dos fluxos das valvas aórtica e pulmonar com ecocardiografia Doppler pulsátil em cães clinicamente sadios
Palabras clave en portugués
Cães sadios
Doppler pulsátil
Ecocardiografia Doppler
Resumen en portugués
O objetivo do presente estudo foi avaliar os fluxos das valvas aórtica (AO) e pulmonar (Pul) por meio de análise qualitativa (presença de regurgitações valvares e características do espectro avaliado) e quantitativa, com obtenção de parâmetros ecocardiográficos como velocidades máxima (V. Max.) e média (V. Me.), integral de velocidade (VTI), tempo de aceleração (TA) e ejeção (TE), volume sistólico (VS) e débito cardíaco (DC). Foram utilizados 30 cães, que após considerados clinicamente sadios por meio de exames físico, laboratoriais, eletrocardiográfico, ecocardiográfico (modos uni e bidimensional), radiográfico de tórax e mensuração da pressão arterial sistêmica, obtiveram-se os seguintes resultados para os referidos parâmetros: V.max. AO= 1,215 + 19,38 m/s; V. Me. AO= 0,722 + 0,08206 m/s; VTI AO= 0,141 + 0,02426m; TA AO= 38,80 + 11,29 ms; TE AO= 197,9 + 24,77 ms; VS AO= 29,63 + 14,59 mL; DC AO= 2,940 + 1,260 L/ min.; V. Max. Pul= 0,9457 + 0,1792 m/s; V. Me. Pul= 0,632 + 0,09960 m/s; VTI Pul= 0,1267 + 0,02324 m; TA Pul= 70,97 + 18,87 ms; TE Pul= 203,7 + 28,98 ms; VS Pul= 28,52 + 17,96 mL; DC Pul= 3,056 + 1,546 L/ min.. Em apenas três animais observou-se regurgitação pulmonar. Alguns parâmetros tiveram correlação negativa com a variável freqüência cardíaca (VTI AO, TE AO, VTI Pul, TA Pul, TE Pul, VS Pul), outros correlação positiva com a variável peso (VTI AO, TA AO, TE AO, VS AO, DC AO, VTI Pul, TE Pul, VS Pul, DC Pul), não sendo encontrada influência da variável sexo na maioria dos parâmetros avaliados. Na comparação entre os dois fluxos, observaram-se V. Max. AO e V. Me. AO maiores que V. Max. Pul. e V. Me. Pul., respectivamente, VTI AO maior que VTI Pul, e TA AO menor que TA Pul. Observada ainda uma correlação positiva e significativa entre VS AO e VS Pul e entre DC AO e DC Pul.
Título en inglés
Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in clinically normal dogs
Palabras clave en inglés
Doppler Echocardiography
Healthy dogs
Pulsed-wave Doppler
Resumen en inglés
The purpose of this study was the evaluation of aortic (AO) and pulmonary (Pul) valves flow for the qualitative (valvar insufficiency presence, characteristic of flow profile) and quantitative analysis, obtaining this way chocardiographic parameters as: peak (PV) and mean (MV) velocities, velocity-time integral (VTI), acceleration (AT) and ejection (ET) time, stroke volume (SV) and cardiac output (CO). Thirty dogs were studied, and to be considered normal, physical, laboratory, electrocardiographic, echocardiographic (uni and bidimensional mode) exams, torax radiographs, and measurement of the blood pressure were accomplished, and the following echocardiographic parameters were obtained: AO PV= 1,215 19,38 m/s; AO MV= 0,722 + 0,08206 m/s; AO VTI= 0,141 + 0,02426m; AO AT= 38,80 + 11,29 ms; AO ET= 197,9 + 24,77 ms; AO SV= 29,63 + 14,59 mL; AO CO= 2,940 + 1,260 L/ min.; Pul PV= 0,9457 + 0,1792 m/s; Pul MV= 0,632 + 0,09960 m/s; Pul VTI= 0,1267 + 0,02324 m; Pul AT= 70,97 + 18,87 ms; Pul ET= 203,7 + 28,98 ms; Pul SV= 28,52 + 17,96 mL; Pul CO= 3,056 + 1,546 L/ min. The variable heart rate had negative correlation with AO VTI, AO ET, Pul VTI, Pul AT, Pul ET, Pul SV, and the variable weight had positive correlation with AO VTI, AO AT, AO ET, AO SV, AO CO, Pul VTI, Pul ET, Pul SV, Pul CO, differently from the variable sex, that had no influence on the evaluated parameters. The comparation of aortic and pulmonary valves flow demonstrated AO PV and AO MV higher than Pul PV and Pul MV, respectively, AO VTI higher than Pul VTI, and Pul AT higher than AO AT. The statistical evaluation also showed a strong and positive correlation between AO SV and Pul SV and between AO CO and Pul CO.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2007-09-11
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.