• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.10.2006.tde-23082007-132820
Documento
Autor
Nome completo
Lilian Caram Petrus
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2006
Orientador
Banca examinadora
Larsson, Maria Helena Matiko Akao (Presidente)
Fernandes, Wilson Roberto
Schwartz, Denise Saretta
Título em português
Avaliação dos fluxos das valvas aórtica e pulmonar com ecocardiografia Doppler pulsátil em cães clinicamente sadios
Palavras-chave em português
Cães sadios
Doppler pulsátil
Ecocardiografia Doppler
Resumo em português
O objetivo do presente estudo foi avaliar os fluxos das valvas aórtica (AO) e pulmonar (Pul) por meio de análise qualitativa (presença de regurgitações valvares e características do espectro avaliado) e quantitativa, com obtenção de parâmetros ecocardiográficos como velocidades máxima (V. Max.) e média (V. Me.), integral de velocidade (VTI), tempo de aceleração (TA) e ejeção (TE), volume sistólico (VS) e débito cardíaco (DC). Foram utilizados 30 cães, que após considerados clinicamente sadios por meio de exames físico, laboratoriais, eletrocardiográfico, ecocardiográfico (modos uni e bidimensional), radiográfico de tórax e mensuração da pressão arterial sistêmica, obtiveram-se os seguintes resultados para os referidos parâmetros: V.max. AO= 1,215 + 19,38 m/s; V. Me. AO= 0,722 + 0,08206 m/s; VTI AO= 0,141 + 0,02426m; TA AO= 38,80 + 11,29 ms; TE AO= 197,9 + 24,77 ms; VS AO= 29,63 + 14,59 mL; DC AO= 2,940 + 1,260 L/ min.; V. Max. Pul= 0,9457 + 0,1792 m/s; V. Me. Pul= 0,632 + 0,09960 m/s; VTI Pul= 0,1267 + 0,02324 m; TA Pul= 70,97 + 18,87 ms; TE Pul= 203,7 + 28,98 ms; VS Pul= 28,52 + 17,96 mL; DC Pul= 3,056 + 1,546 L/ min.. Em apenas três animais observou-se regurgitação pulmonar. Alguns parâmetros tiveram correlação negativa com a variável freqüência cardíaca (VTI AO, TE AO, VTI Pul, TA Pul, TE Pul, VS Pul), outros correlação positiva com a variável peso (VTI AO, TA AO, TE AO, VS AO, DC AO, VTI Pul, TE Pul, VS Pul, DC Pul), não sendo encontrada influência da variável sexo na maioria dos parâmetros avaliados. Na comparação entre os dois fluxos, observaram-se V. Max. AO e V. Me. AO maiores que V. Max. Pul. e V. Me. Pul., respectivamente, VTI AO maior que VTI Pul, e TA AO menor que TA Pul. Observada ainda uma correlação positiva e significativa entre VS AO e VS Pul e entre DC AO e DC Pul.
Título em inglês
Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in clinically normal dogs
Palavras-chave em inglês
Doppler Echocardiography
Healthy dogs
Pulsed-wave Doppler
Resumo em inglês
The purpose of this study was the evaluation of aortic (AO) and pulmonary (Pul) valves flow for the qualitative (valvar insufficiency presence, characteristic of flow profile) and quantitative analysis, obtaining this way chocardiographic parameters as: peak (PV) and mean (MV) velocities, velocity-time integral (VTI), acceleration (AT) and ejection (ET) time, stroke volume (SV) and cardiac output (CO). Thirty dogs were studied, and to be considered normal, physical, laboratory, electrocardiographic, echocardiographic (uni and bidimensional mode) exams, torax radiographs, and measurement of the blood pressure were accomplished, and the following echocardiographic parameters were obtained: AO PV= 1,215 19,38 m/s; AO MV= 0,722 + 0,08206 m/s; AO VTI= 0,141 + 0,02426m; AO AT= 38,80 + 11,29 ms; AO ET= 197,9 + 24,77 ms; AO SV= 29,63 + 14,59 mL; AO CO= 2,940 + 1,260 L/ min.; Pul PV= 0,9457 + 0,1792 m/s; Pul MV= 0,632 + 0,09960 m/s; Pul VTI= 0,1267 + 0,02324 m; Pul AT= 70,97 + 18,87 ms; Pul ET= 203,7 + 28,98 ms; Pul SV= 28,52 + 17,96 mL; Pul CO= 3,056 + 1,546 L/ min. The variable heart rate had negative correlation with AO VTI, AO ET, Pul VTI, Pul AT, Pul ET, Pul SV, and the variable weight had positive correlation with AO VTI, AO AT, AO ET, AO SV, AO CO, Pul VTI, Pul ET, Pul SV, Pul CO, differently from the variable sex, that had no influence on the evaluated parameters. The comparation of aortic and pulmonary valves flow demonstrated AO PV and AO MV higher than Pul PV and Pul MV, respectively, AO VTI higher than Pul VTI, and Pul AT higher than AO AT. The statistical evaluation also showed a strong and positive correlation between AO SV and Pul SV and between AO CO and Pul CO.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2007-09-11
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.