• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.10.2016.tde-07102015-105755
Document
Author
Full name
Ronaldo Gomes Gargano
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2015
Supervisor
Committee
Pogliani, Fabio Celidonio (President)
Birgel Junior, Eduardo Harry
Ollhoff, Rudiger Daniel
Title in Portuguese
Ultrassonografia Doppler do fluxo arterial digital associado à alteração do coxim digital dos bovinos
Keywords in Portuguese
Doppler pulsado
Fluxo de sangue
Lesões podais
Úlcera de sola
Abstract in Portuguese
O objetivo do estudo foi avaliar, por meio da ultrassonografia bidimensional e da ultrassonografia Doppler, as inter-relações entre a alteração de espessura do coxim digital com os índices vasculares da artéria digital dorsal comum dos membros pélvicos dos bovinos. A avaliação ultrassonográfica Doppler é uma técnica não invasiva de avaliação de índices vasculares, assim como, indiretamente, do volume de sangue do leito vascular. Para isso, foram realizados exames ultrassonográficos da espessura do coxim digital e também avaliação ultrassonográfica Doppler da referida artéria de 13 vacas primíparas da raça Holandesa, em intervalos de 14 dias, durante 126 dias após o parto. Ao longo do experimento o coxim digital apresentou diminuição não significativa de espessura (p=0,1715) e apresentou forte correlação positiva com a média do escore de condição corporal (p=0,03, r=0,71). Ao longo do período avaliado, o fluxo de sangue aumentou significativamente (p<0,0001) e apresentou correlação negativa com os índices que denotam impedância ao deslocamento de sangue, isto é, índice de resistividade (p<0,0001, r=-0,34911) e pulsatilidade (p<0,0001, r=-0,5035). Além disso, realizou-se correlação entre a diferença diária do fluxo de sangue e a diferença da espessura do coxim digital para cada animal e constatou-se uma forte tendência à correlação entre as diferenças das variáveis (p=0,0515, r=-0,5729). Por meio dos resultados encontrados foi possível concluir que o escore de condição corporal teve forte correlação com a espessura do coxim digital, ao longo do estudo. Além disso, o fluxo de sangue, os índices referentes à velocidade de deslocamento das hemácias e o diâmetro da artéria aumentaram ao longo do trabalho. E, também, que a discreta diminuição do coxim digital não foi um fator que influenciou no aumento do fluxo de sangue e nos índices vasculares
Title in English
Doppler ultrasonography of digital blood flow associated with changes in bovine digital cushion
Keywords in English
Blood Flow
Claw lesions
Pulsed Doppler
Sole ulcer
Vascular indices
Abstract in English
The aim of this study was to evaluate, by bidimensional and pused Doppler ultrasound, the interrelationship between the changes of the thickness of digital cushion with vascular indices of the common dorsal digital artery of the hind limbs of cattle. Pused Doppler sonography is a non-invasive tool to assessment the vascular indices, as well as, the blood flow volume in vascular bed. So, were performed ultrasound exams of soft tissue thickness and also the Doppler ultrasonographic evaluation of that artery in thirteen first lactation Holstein cows and followed them up during 126 days in milk. Throughout the experiment the digital cushion showed a slight decrease without significance (p=0,1715), this also was strongly correlated with body condition score (p=0,03, r=0,71). The blood flow volume had significance increase (p<0,0001) and was negatively correlated with both impedance indices, resistance index (P<0,0001 r =-0,34911) and pulsatility index (p <0,0001 r =-0,5035). In addition, a correlation was performed with both daily differences of the blood flow and the thickness of the digital cushion for each animal and it was observed a strong tendency of correlation between the different variables (p=0,0515 r =-0,5729). Therefore, we can conclude that body condition score was strong correlated with the thickness of digital cushion, throughout the study. In addition, the blood flow volume, the velocity indices and the artery diameter increase throughout the days in milk. And, so, the slight decrease in the thickness of digital cushion was not a factor that influenced the increase of blood flow and vascular indices
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2016-04-05
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.