• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.10.2011.tde-01062012-165319
Documento
Autor
Nome completo
Arine Pellegrino
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2010
Orientador
Banca examinadora
Larsson, Maria Helena Matiko Akao (Presidente)
Pereira, Guilherme Gonçalves
Schwartz, Denise Saretta
Título em português
Ecocardiografia tecidual em gatos da raça Maine Coon geneticamente testados para a cardiomipatia hipertrófica
Palavras-chave em português
Cardiomiopatia hipertrófica
Doppler tecidual
Ecocardiografia
Gatos
Maine Coon
Resumo em português
A cardiomiopatia hipertrófica (CMH) é a principal cardiopatia dos felinos e é caracterizada por hipertrofia miocárdica concêntrica, sem dilatação ventricular. Disfunções miocárdicas ocorrem em gatos com CMH, mas pouco se conhece a respeito destas alterações nos estágios iniciais da afecção. Em gatos da raça Maine Coon, a mutação no gene MyBPC-A31P está relacionada com a CMH de origem familial, porém, a correlação exata entre o genótipo e o fenótipo ainda é inconclusiva. A ecocardiografia tecidual é uma modalidade não invasiva que permite avaliação da função miocárdica e é mais sensível que a ecocardiografia convencional. Para avaliar a função sistólica e diastólica, antes ou após a ocorrência de hipertrofia ventricular, gatos da raça Maine Coon (n=57), geneticamente testados para a mutação, foram avaliados por meio de ecocardiografia convencional e tecidual (nas modalidades Doppler tecidual pulsado, Doppler tecidual colorido e strain). Posteriormente, foram fenotipicamente classificados em: normais (n=45), suspeitos (n=7) e acometidos pela CMH (n=5); e genotipicamente classificados em: negativos (n=28), heterozigotos (n=26) e homozigotos para a mutação (n=3). Valores de velocidades miocárdicas (Doppler tecidual pulsado e colorido) e valores de strain, medidos na região basal e média do septo interventricular (SIV), da parede livre do ventrículo esquerdo (PVE), da parede anterior do ventrículo esquerdo (PAVE), da parede posterior do ventrículo esquerdo (PPVE) e do segmento radial da PVE, foram comparados nos diferentes grupos. Observou-se que as velocidades longitudinais Em (Doppler tecidual pulsado) na região média da PVE foram menores nos gatos com CMH quando comparados com suspeitos e normais. Os valores de Em/Am (Doppler tecidual colorido), na região basal do SIV, foram inferiores nos gatos com CMH quando comparados com suspeitos e normais. A relação E/Em (Doppler tecidual colorido), na região basal do SIV, foi maior nos gatos com CMH em relação aos suspeitos e normais. E os valores de Sm (Doppler tecidual colorido), em região basal da PVE, foram menores nos gatos heterozigotos em relação aos negativos, ambos sem hipertrofia ventricular. Observou-se correlação positiva entre a ocorrência de fusão das ondas Em e Am e a frequência cardíaca; e correlação positiva entre valores de Sm e Em e a frequência cardíaca (Doppler tecidual pulsado e colorido). Enquanto à ecocardiografia convencional observou-se um estado de contratilidade aparentemente normal, os valores de strain (em região média do SIV) nos gatos com CMH foram inferiores aos dos gatos normais. Valores de strain (em região basal da PAVE) também foram menores nos gatos heterozigotos em relação aos negativos, antes mesmo da hipertrofia ventricular. Observou-se correlação negativa entre valores de strain e espessura miocárdica. A ecocardiografia tecidual é uma nova modalidade ecocardiográfica reprodutível em gatos que, isoladamente, não permite a identificação de gatos com mutação antes do desenvolvimento de hipertrofia. O strain possibilita a detecção de anormalidades sistólicas em gatos da raça Maine Coon, apesar da aparente normalidade à ecocardiografia convencional. Apesar da expectativa em relação ao uso da ecocardiografia tecidual para a identificação precoce de indivíduos portadores da CMH, ainda há necessidade de estudos mais extensos e com maior número de indivíduos.
Título em inglês
Tissue Doppler echocardiography in Maine Coon cats genetically tested for hypertrophic cardiomyopathy
Palavras-chave em inglês
Cats
Echocardiography
Hypertrophic cardiomyopathy
Maine Coon
Tissue Doppler
Resumo em inglês
Hypertrophic cardiomyopathy (HCM) is the most common feline heart disease and is characterized by increased cardiac mass with a hypertrophied nondilated left ventricle. Myocardial dysfunction occurs in cats with HCM but less is known about dysfunctions in initial stages of HCM. A mutation in MYBPC-A31P gene has been identified in a colony of Maine Coon cats with HCM. However, the close correlation between genotype and phenotype still be inconclusive. Myocardial analysis by tissue Doppler imaging (TDI) is a noninvasive echocardiographic method to assess systolic and diastolic function that is more sensitive than conventional echocardiography. To evaluate diastolic and systolic function in cats with mutation, with or without ventricular hypertrophy, Maine Coon cats (n=57) were screened for mutation and examined with both echocardiography and TDI (pulsed tissue Doppler, color tissue Doppler and Strain methods). Then, were phenotypically classified in: normal (n=45), suspects (n=7) and HCM group (n=5); and genotypically classified in: negative (n=28), heterozygous (n=26) and homozygous group (n=3). Myocardial velocities (by pulsed and color tissue Doppler imaging) and peak myocardial strain, measured in the basal and mildventricular segment of the interventricular septal wall (IVS), left ventricular free wall (LVW), left ventricular anterior wall (LVAW), left ventricular posterior wall (LVPW) and radial segment of LVW, was compared among different groups. A decreased longitudinal Em velocities (pulsed tissue Doppler) at the mildventricular segment of LVW was observed in HCM cats compared with suspects and normal cats. A decreased longitudinal Em/Am (color tissue Doppler) at the basal segment of IVS was observed in HCM cats compared with suspects and normal cats. A significant increased longitudinal E/Em (color tissue Doppler) at the basal segment of IVS was observed in HCM cats compared with suspects and normal cats. And a significant decreased longitudinal Sm (color tissue Doppler) at the basal segment of the LVW was observed in heterozygous cats compared with negative cats, both without hypertrophy. There was a positive correlation between summated early and late diastolic velocities (EmAm) and heart rate; and a positive correlation between Sm and Em velocities and heart rate, both in pulsed and in color TDI. Whereas conventional echocardiography demonstrated an apparently normal contractile state, myocardial strain (at mildventricular segment of IVS) in HCM cats was decreased compared with normal group. Myocardial strain (at basal segment of LVAW) also was decreased in heterozygous cats compared with negative group; and was decreased in heterozygous cats compared with negative group, both without ventricular hypertrophy. And there was a negative correlation between strain values and wall thickness. TDI analyses are a new, valuable and reproducible method in cats that alone is not able to identify cats with mutation before myocardial hypertrophy. Strain method allows noninvasive detection of abnormal systolic deformation in Maine Coons cats with HCM mutation despite apparently normal left ventricular systolic function. Despite high expectations regarding the use of TDI for early identification of individuals with HCM, there is still need for larger studies with greater numbers of individuals.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
ARINE_PELLEGRINO.pdf (4.54 Mbytes)
Data de Publicação
2012-10-09
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.